Sensitivity Adjustment - Takex OMS-12FE Instruction Manual

Dual zone outdoor pir
Table of Contents

Advertisement

5
SETTING
Mode setting
switches
OPERATION LED (switch1)
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
The display cannot be set to OFF for warm-up period,
device trouble, or low power supply voltage.
ALARM CONTACT (switch2)
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
AREA SELECT (switch5,6)
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF
1 2 3 4 5 6 7 8
ON
OFF

SENSITIVITY ADJUSTMENT

The sensor can be adjusted in accordance with the environment and
intended purpose.
Normally, use medium (100%).
Setting the sensitivity to 170% will trigger detection even at small changes
in temperature.
Use this in stable environments.
Setting the sensitivity to 30% will not trigger detection unless there is a
large change in temperature.
Use this in environments which are subject to large changes in temperature.
When changing the sensitivity dial, ensure that a walk test is carried out to check that the sensitivity is suitable.
ON
[Factory set]
OFF
NORMAL
N.O.
ALARM
NORMAL
N.C.
[Factory set]
ALARM
Regardless of the
settings of switch 6,
Use 180°
the sensor will cover
area
a 180° detection area.
[Factory set]
The right area is
disabled.
Use left
90° area
The left area is
disabled.
Use right
90° area
30%
170%
PULSE COUNT (switch3,4)
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Right side
Left side
Right side
Left side
Sensitivity can be adjusted
between 30% and 170%.
[Factory set : 100%]
Set for sensitive detection of even
small movements by people, however
this may be more susceptible to false
alarms.
ON
1
OFF
For wall detection, use this setting.
In normal operation, use this setting.
ON
2
OFF
[Factory set]
This setting is suitable for locations with
frequent changes in temperature.
ON
3
This is not as susceptible to false
alarms as pulse count 2, however this
OFF
is also not as sensitive to people.
This is not as susceptible to false
ON
alarms as pulse count 3, however this
4
is also not as sensitive to people.
OFF
FACTORY SET
1 2 3 4 5 6 7 8
Switches 7 and 8 are not used.
Ensure these are OFF during
operation.
ON
OFF