Parts Description - Takex OMS-12FE Instruction Manual

Dual zone outdoor pir
Table of Contents

Advertisement

1

PARTS DESCRIPTION

Please confirm that the sensor and all parts are included in the packaging.
1-1
PARTS
Lens
Cover
1-3
OPERATIONAL PARTS TITLES AND FUNCTIONS
Sensitivity adjustment : Dial to adjust detection sensitivity
Mode setting switches : Indicator LED, contact logic, pulse count, and area selection DIP switches
Adjustment holder
2
PRECAUTIONS
Description of the Display
Warning
This mark indicates details regarding handling which, if ignored, may result in death or injury.
This mark indicates details regarding handling which, if ignored, may result in delays in reporting
Caution
attributable to false or missed alarms.
This mark indicates a prohibition, with the item shown in
the mark specifically prohibited.
This mark indicates points of which the user should be aware.
Ensure that you do not disassemble or alter this
product, as this may lead to fire, electric shock, or
damage.
In the event of an abnormal condition such as smoke
or unusual smells or sounds being emitted,
immediately stop power supply to the device, confirm
that smoke is no longer being emitted, and request
repair from the retailer. Continuing to use the sensor
in this condition may lead to fire or electric shock.
Do not connect devices that exceed the capacitance as
shown on the output terminal. Doing so may cause
fire.
Do not use the sensor with voltages other than as
specified (9 to 28V DC). Doing so may cause fire or
electric shock.
Pole mounting bracket knockout
(use for pole mounting option)
[7-2 Installation Method]
Sensitivity
adjustment
[5 SETTING]
Mode
setting
switches
[5 SETTING]
Operation LED
[4 FUNCTION]
Cover locking screw
[7 INSTALLATION]
Body
: Part to adjust detection distance
The following marks indicate precautions that should be adhered to in order that this
product can be used safely. These are important; therefore ensure that you read these
carefully.
Wall mounting knockout
[7-2 Installation Method]
Wiring hole
[6 WIRING]
Terminal
[6 WIRING]
Adjustment index
[3-2 Area Adjustment]
Tamper switch
[4 FUNCTION]
Holder locking screw
[3-2 Area Adjustment]
Adjustment holder
[3-2 Area Adjustment]
Wall mounting knockout
[7-2 Installation Method]
Pole mounting bracket
knockout
(use for pole mounting option)
[7-2 Installation Method]
Example:
Warning
Ensure that the sensor is mounted in a strong location
such as over a reinforcing beam on the wall. When
mounting on surfaces other than wood such as
plasterboard or concrete, ensure that the sensor is
securely affixed using anchors and screws suited to the
surface material. If the sensor should fall off, this could
result in injury or damage.
In the event of water entering the sensor, immediately
stop power supply to the device, and contact the retailer.
Continuing to use the sensor in this condition may lead
to fire or electric shock.
Do not use the sensor in bathrooms or other locations
with high humidity. Doing so may cause fire or electric
shock.
1-2
Accessory
Instruction Manual
Area masking sheet (4set)
[3-3 AREA MASKING]
Self tapping screw
( 4x35)2 pcs
[7-2 INSTALLATION METHOD]
Back tamper rubber
[4 FUNCTION]
[5 SETTING]
[5 SETTING]
[3 DETECTION AREA]
Disassembly prohibited

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents