Detection Area; Area Adjustment - Takex OMS-12FE Instruction Manual

Dual zone outdoor pir
Table of Contents

Advertisement

3

DETECTION AREA

3-1
Detection Area
<Default detection area>
40'(12m)
33'(10m)
16.5'(5m)
[TOP VIEW]
0
Horizontal
Detection
16.5'(5m)
33'(10m)
40'(12m)
[SIDE VIEW]
3.3'
(1m)
0
Variable
range
3-2

Area Adjustment

possible by adjusting the angle of the downward zone).
Adjusting the detection distance adjustment holder position up and down
changes the detection distance. (The detection distance can be changed
between 10' to 40' (approx. 3m to 12 m)
(1) Remove the cover.
(2) Loosen the detection distance adjustment holder locking screw.
(3) Referring to the index, move the holder up to move the detection
distance closer, and down to move the detection distance further away.
(4) Tighten the locking screw to set the detection distance.
When using at 12m distance
Mark
The sensor has two areas, right and left, and each area has two zones of detection — the horizontal zone and
the downward zone. The system initiates an alarm when detection occurs in both of these in a same area
simultaneously. If changes in temperature occur to the left and right area in different zones simultaneously,
(e.g. the left horizontal zone and the right downward zone), this will not be interpreted as detection.
40'
(12m)
Horizontal Zone
16.5'
40'
33'
(5m)
(10m)
(12m)
Downward Zone
[7-1 Removing the Cover]
Horizontal zone
Detection range
<Detection area after adjustment of detection distance>
Please refer to 3-2 Area Adjustment.
[SIDE VIEW]
3.3'
(1m)
0
16.5'
33'
(5m)
(10m)
3.3'
(1m)
0
16.5'
33'
(5m)
(10m)
3.3'
(1m)
0
16.5'
33'
(5m)
(10m)
3.3'
(1m)
0
16.5'
33'
(5m)
(10m)
3.3'
(1m)
0
16.5'
33'
(5m)
(10m)
Detection distance is set by adjusting the angle of downward zone.
Adjustable range 10' (3m) to 40' (12m). [9 ranges]
Closer
distance
detection
Further
distance
detection
When using at 3m distance
Mark
Detection range
40'
(12m)
40'
(12m)
DETECTION DISTANCE
40'
(12m)
40'(12m)
26'(8m)
16'(5m)
13'(4m)
10'(3m)
40'
(12m)
40'
(12m)
Index
Holder locking
screw
Do not loosen this screw.
The lower holder is fixed.
Horizontal zone
Not detected