Page 1
RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up User Guide PIMA Electronic Systems Ltd. 5 Hatzoref Street, Holon 58856, Israel ℡ +972-3-6506444 +972-3-5500442 support@pima-alarms.com http://www.pima-alarms.com...
Page 2
PIMA’s prior written consent is granted. All efforts have been made to ensure that the content of this manual is accurate. Pima retains the right to modify this manual or any part thereof, from time to time, without serving any prior notice of such modification.
RXN-406 Keypad for CAPTAIN-i - User Guide Table of Contents Introduction..................3 Main Features of CAPTAIN-i ..............4 Access and Operation Codes ..............4 LED Description...................6 System Functions ................7 Programming Functions ..............9 SAFETY INSTRUCTIONS Your CAPTAIN-i alarm system has been registered in accordance with EN60950 and its rules. EN 60950 requires us to advise you the following information: 1.
♦ Various modes of arming and disarming: keypad, key, remote control, automatic ♦ Four types of keypads: A simple LED keypad (RX-406 or RX-6), LCD keypads (RXN-400 or RXN-410) and Anti-vandal keypad RX/N-200 ♦ Up to six different keypads, connected in parallel ♦...
Page 5
If the system is disarmed, the code will send a silent duress event to the MS The RX-406 keypad features 6 zone LEDs and 7 information LEDs as described in the following drawing and table (next page). These LEDs provide zone status information, as well as system status & fault...
The six red lights in the The green ARMED light display area of the keypad provides the system Arm provide the zone status status as follows: RX-406 information for the six Off: System is corresponding numbered disarmed. zones, as follows:...
RXN-406 Keypad for CAPTAIN-i - User Guide YSTEM UNCTIONS IMPORTANT! symbol indicates information that you must enter. To arm/disarm Partition #1: User Code To arm/disarm Partition #2: User Code To arm/disarm the entire Alarm System: Any User Code that belongs to either partitions OR Short Code.
Page 8
RXN-406 Keypad for CAPTAIN-i - User Guide NOTE: When Bypass mode is executed, it is effective until you disarm the system. To reset the smoke or fire detector: Press and hold three seconds till confirmation beep. To identify the last zone(s) that caused an alarm: Press and hold .
RXN-406 Keypad for CAPTAIN-i - User Guide To initiate a PANIC Response: Press and hold simultaneously for two seconds. NOTE: You can customize your system's response to a panic event, for example, calling the Monitoring Station or your private telephone number. Consult your installer about programming a Panic Response.
Page 10
RXN-406 Keypad for CAPTAIN-i - User Guide To delete User Code #1: Primary Code To program User Codes #2 to #8: Primary Code (as many as the User Code number) new User Code (4-6 digits) To delete User Code #2 to #8: Primary Code (as many as the User Code number) Example:...
Page 11
RXN-406 Keypad for CAPTAIN-i - User Guide To delete a Short Code: Primary Code BACK To program system’s automatic arming time: Primary Code Hour (in HH format) Minutes (in MM format) To cancel system’s automatic arming: To program telephone numbers: Primary Code first (area code) telephone number second (area code)
Page 12
RXN-406 Keypad for CAPTAIN-i - User Guide To delete all private telephone numbers: Primary Code To set the time and date for the system: Primary Code 2 digits for the current hour 2 digits for the current minutes last 2 digits of the current year 2 digits for the current month 2 digits for the current day...