Lab.gruppen C 68:4 Operation Manual page 29

C series installation-dedicated amplifiers
Hide thumbs Also See for C 68:4:
Table of Contents

Advertisement

Rated
Level
Load
power
Standby w. remote Power Off via NomadLink
Power On, Idling
1/8 of
700 x4
8 Ω / Ch.
rated
16 Ω / Bridged
1400 x2
power
700 x4
4 Ω / Ch.
(Pink noise,
1400 x2
8 Ω / Bridged
12 dB crest
2 Ω / Ch.
300 x4
factor)
4 Ω / Bridged
600 x2
700 x4
100V / Ch.
1400 x2
200V / Bridged
Max.
700 x4
8 Ω / Ch.
16 Ω / Bridged
1400 x2
*3)
power
4 Ω / Ch.
700 x4
(Pink noise,
1400 x2
8 Ω / Bridged
6dB crest
300 x4
4 Ω / Ch.
factor)
8 Ω / Bridged
600 x2
100V / Ch.
700 x4
1400 x2
200V / Bridged
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct.
specified here is what is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat
dissipation.
*2) Current draw figures measured at 230V. 115V figures are 230V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features kicks in. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will never occour during normal operation. Also note that the mains breaker will
not be tripped even it's in excess of max. ratings.
Rated
Level
Load
power
Standby w. remote Power Off via NomadLink
Power On, Idling
1/8 of
400 x4
8 Ω / Ch.
rated
16 Ω / Bridged
800 x2
power
300 x4
4 Ω / Ch.
(Pink noise,
600 x2
8 Ω / Bridged
12 dB crest
2 Ω / Ch.
n.r.
factor)
4 Ω / Bridged
n.r.
400 x4
100V / Ch.
800 x2
200V / Bridged
Max.
400 x4
8 Ω / Ch.
16 Ω / Bridged
800 x2
*3)
power
4 Ω / Ch.
300 x4
(Pink noise,
600 x2
8 Ω / Bridged
6dB crest
2 Ω / Ch.
n.r.
factor)
4 Ω / Bridged
n.r.
400 x4
100V / Ch.
800 x2
200V / Bridged
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct.
specified here is what is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat
dissipation.
*2) Current draw figures measured at 230V. 115V figures are 230V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features kicks in. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will never occour during normal operation. Also note that the mains breaker will
not be tripped even it's in excess of max. ratings.
C 28:4
Line Current
Watt
*1)
115VAC 230VAC
In
Out
Dissipated
0
0
123
0
Amp (I)
W
*2)
11,6
5,8
727
350
13,0
6,5
775
350
9,4
4,7
529
150
10,4
5,2
663
350
24,0
12,0
1589
933
20,8
10,4
1359
700
14,0
7,0
843
300
21,4
10,7
1458
933
16 A, CEE7
20 A / 5-20P
C 16:4
Line Current
Watt
*1)
115VAC 230VAC
In
Out
Dissipated
0
0
129
0
Amp (I)
W
*2)
8,6
4,3
526
200
8,2
4,1
485
150
7,6
3,8
463
200
16,2
8,1
1046
533
15,2
7,6
953
400
14,4
7,2
944
533
16 A, CEE7
15 A / 5-15P
APPENDIX 8
Thermal Dissipation
BTU/hr
kCal/hr
0
0
0
123
420
106
377
1286
324
425
1450
365
379
1293
326
313
1068
269
656
2237
564
659
2249
567
543
1853
467
525
1790
451
Instead, measured and
Thermal Dissipation
BTU/hr
kCal/hr
0
0
0
129
440
111
326
1112
280
335
1143
288
263
897
226
513
1749
441
553
1887
475
411
1401
353
Instead, measured and
C Series Operation Manual 9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C 68:4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

C 48:4C 28:4C 16:4

Table of Contents