2.4

RATING PLATE INFORMATION

THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE ONLY WITH
A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN
THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOTAPPLICABLE USE
THE
STANDARD
FOR
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
FOR USE WITH GLASS DOORS CERTIFIED WITH
THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE
APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED
BY THE MANUFACTURER WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING THE
APPROPRIATE WOLF STEEL VENT KITS. SEE
OWNERS INSTALLATION MANUAL FOR VENTING
SPECIFICS.
MINIMUM AND MAXIMUM VERTICAL VENT
LENGTHS ARE 3 FEETAND 40 FEET
RESPECTIVELY.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see "INSTALLATION OVERVIEW" section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.22b-2009, ANSI 21.50b-2009 VENTED GAS FIREPLACE / FOYER AU GAZ AVEC EVACUATION.
FIRE
SAFETY
CRITERIA
FOR
MANUFACTURED
9700539 (WSL)
4001658 (NAC)
GDS20N / CDVS20N
0-4500FT (0-1370m)
COLONNE D'EAU(GN)
20,000 BTU/h
13,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
COLONNE D'EAU (GN)
COLONNE D'EAU (GN)
NOT FOR USE WITH SOLID FUEL
D FUEL
EL
MINIMUM AND MAXIMUM HORIZONTAL VENT
AXIMUM HORIZONTAL VENT
ZONTAL VENT
LENGTHS ARE 12 INCHES AND 20 FEET
12 INCHES AND 20 FEET
2 INCHES AND 20 FEET
RESPECTIVELY.
ELY.
LY.
PROPER REINSTALLATION AND RESEALING IS
REINSTALLATION AND RESEALING IS
EINSTALLATION AND RESEALING IS
NECESSARY AFTER SERVICING THE VENT-AIR
SARY AFTER SERVICING THE VENT-AIR
RY AFTER SERVICING THE VENT-AIR
INTAKE SYSTEM.
KE SYSTEM.
TEM.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
IMUM CLEARANCE TO COMBUSTIBLE MATE
ARANCE TO COMBUSTIBLE MAT
4"
4" 4
A A
A
G G
2" 2"
2"
B B
B
2"
2"
C
C C
VENT TOP
VENT TOP
VENT TOP
2"
2"
2"
TO CEILING FROM
TO
T
VENT BOTTOM
VENT BOTTOM
VENT BOTTOM
1"
1"
1"
STOVE TOP
VENT SIDES
VENT SIDES
VENT SIDES
1"
1
1"
IE, ON, L4M 0G8 CA
N, L4M 0G8 C
LACE / FOYER AU GAZ AVEC EVA
ACE / FOYER AU GAZ AVEC EVA
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE. REMPLACEZ
REQUIERT UN THERMOCOUPLE À
UIERT UN THERMOCOUPLE À
UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL
AVEC UN THERMOCOUPLE À ACTIO
THERMOCOUPLE À ACTI
LTÉE.HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE
OGUE POUR INSTALLATION DANS UNE
DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
T UN STUDIO. APPROPRIE POUR INSTAL
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE
TALLATION CONFORME AUX EXIGENCE
TALLATION CONFORME AUX EXIGENCE
DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS
AISONS MOBILES EQUIPEES AU GAZ, EN
ISONS MOBILES EQUIPEES AU GAZ, E
DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES,
LA NORME DE SECURITE ET DE CON
NORME DE SECURITE ET DE CON
HOME
TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ITRE 24 CFR, SECTION 3280. DANS LE
4 CFR, SECTION 3280. DANS L
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE
ETRE APPLIQUEE, SE REFERER A LA
ETRE APPLIQUEE, SE REFERER A LA
SECURITE CONTRE L'INCENDIE
SECURITE CONTRE L'INCENDIE
SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTUR
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MANUFACTUR
4001657 (NGZ)
4001657 (NGZ)
4001657
4001659 (WUSA)
4001659 (WUSA)
4001659
MODEL
MODEL
MODEL
GDS20P / CDVS20P
GDS20
ALTITUDE / ELEVATION
TITUDE / ELEVATION
TITUDE / ELEVATION
0-4500
0-4500FT (0-1370m)
INPUT / ALIMENTATION
INPUT / ALIMENTATION
NPUT / ALIMENTATION
20,000 BTU/h
20,0
ED INPUT / ALIMENTATION REDUITE
D INPUT / ALIMENTATION REDUITE
12,000 BTU/h
1
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL.
UN COM
UN CO
UTIL
UTILIS
UTILISER AVEC LES PORTES VITREES
HO
HO
HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL
A
AUCUN MATERIAU DEVANT ENTRER EN CONTACT
AVEC LES FLAMMES AUTRE QUE CELUI QUI EST
FOURNI AVEC CETAPPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A WOLF
STEEL.
REFERER AU MANUEL D'INSTALLATION DE
PROPRIETAIRE POUR L'EVACUATION PRECISE. LES
LONGUEURS VERTICALES MINIMALES ET
MAXIMALES SONT3 PIEDS ET 40 PIEDS
48"
RESPECTIVEMENT.
GDS/CDVS20
SERIAL NUMBER / NO. DESERIE
STALLATION DANS UNE
PRIE POUR INSTA
MANIFOLD PRESSURE: 10 INCHES W.C. (LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU(P)
MIN SUPPLY PRESSURE: 11" W.C.(LP)
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
LES LONGUEURS HORIZONTALES MINIMALES
ET MAXIMALES SONT 12 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
4"
A
2"
B
2"
C
EVENT SUPERIEUR 2" ENTRE LE DESSUS DU FOYER
EVENT INFERIEUR 1" ET LE PLAFOND
COTES DE L'EVENT 1"