Factory Defaults (Reset) - Bunn SINGLE TF DBC W/SMART FUNNEL Installation & Operating Manual

Table of Contents

Advertisement

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULTS
This function allows the operator to erase all of the
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
Procedure to set factory defaults:
1. Press and hold the ® pad until SET NEW RECIPES
appears. Release the ® pad. Press and release ®
until the display reads FACTORY DEFAULTS.
2. Pressing NO in this screen will revert to the MAIN
SCREEN. Press YES to replace the defaults. This
advances to WILL REPLACE ALL BREWING SET-
TINGS. This screen will alternate with ARE YOU
SURE?.
3. Pressing NO in the confirmation screen will revert
to MAIN SCREEN, without resetting the brewing
setups to the defaults. Press YES to load the
defaults. This will then revert to the MAIN SCREEN,
and the factory default values will replace all
previously entered values. It will NOT reset the
summation Brew counter.
Brew Lockout
BREW VOLUMES:
Small Batch
Medium Batch
Large Batch
BYPASS PERCENTAGE:
Small Batch
Medium Batch
Large Batch
PULSE BREW TIMES:
Small Batch
Medium Batch 1:00 (1st on)- :10 (off)- :20 (last on)
Large Batch
PREINFUSION TIMES:
Small Batch
Medium Batch
P2312
Large Batch
DRIP OUT TIMES:
Small Batch
Medium Batch
Large Batch
ENABLE ADS
BREW TEMPERATURE
READY TEMPERATURE
REFILL
SPRAY (OZ/MINUTE)
BYPASS (OZ/MINUTE)
FUNNEL DETECT
Page 35
FACTORY DEFAULT VALUES
:20 (1st on)- :15 (off)- :05 (last on)
:40 (1st on)- :15 (off)- :20 (last on)
YES
64 oz.
128 oz.
192 oz.
0%
0%
20%
DISABLED
DISABLED
DISABLED
1:00
1:30
2:00
YES
205˚F (96˚C)
195˚F (91˚C)
0 - 155
53
48
YES
35879 082203