Site Requirements; Operator And Service Access; Floor Requirements - Kodak PROFESSIONAL LED II 20P Operator's Manual

Kodak printer user manual
Hide thumbs Also See for PROFESSIONAL LED II 20P:
Table of Contents

Advertisement

Specifications

Site Requirements

2.2 meters + .3 meters (86 in. + 12 in.)
_
1.5 meters (60 in.)
.91 meters (36 in.)
minimum
*
SCSI-2 connection from host here
B-2

Operator and Service Access

When fully assembled the equipment requires a minimum of 91 cm
(36 in.) on each side to allow sufficient access for normal operator maintenance
and for service.
3.5 meters + .3 meters (138 in. + 12 in.)
_
_
.91 meters (36 in.)
minimum
*
Printer
.91 meters (36 in.)
minimum
4.5 meters (179 in.)
4.4 meters (174 in.)

Floor Requirements

The equipment should be installed on a smooth, hard, and level floor surface.
Carpet is not recommended.
The floor pitch should not exceed 1 inch in 5 feet.
_
15A
Processor
30A
2.9 meters
(114 in.)
.91 meters (36 in.)
minimum
September 2000