14 Technical data

Transmission band: ...................................... 868 MHz
Typ. open air range: ................ up to 100 m (open air)
Power supply: ........................................4.5 V/3 x LR6
Degree of protection: .......................................... IP30
Ambient temperature: ..................................0 to 50˚C
Storage temperature: ............................. -25 to +70˚C
Rel. humidity: ..................5 to 93%, non-condensing
Internal signalling device: ...................>85 dB(A)/3 m
Dimensions (D x H): ................................120 x 44 mm
Max. cable length for networking:
Max. number of devices for networking: ...............40
Subject to technical alterations.
Note on disposal:
Do not dispose of the device as part of
household waste! Electronic devices are
to be disposed of in accordance with the
guidelines concerning electrical and electronic
devices via the local collection point for old
electronic devices.
The CE sign is a free trade sign addressed
exclusively to the authorities and does not
include any warranty of any properties.
70
400 m (J-Y(St)Y 2 x 2 x 0.6 mm)