Download Print this page

Electrical Installation - Dimplex PFH30 User Manual

Compact commercial fan heaters

Advertisement

Dimplex Compact Commercial Fan Heater
Models : PFH30 and PFH30R (Remote Control)
IMPORTANT : THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
DO NOT use the heater in the immediate
surroundings of a bath, a shower or a swimming
pool.
DO NOT place the heater directly below a fixed
socket outlet.
DO NOT COVER or obstruct the air inlet and
outlet openings in any way.
DO NOT operate the heater with the mains lead
overhanging the front outlet grille.
The heater carries the warning symbol to
indicate that it must not be covered.
WARNING: In order to avoid overheating do not
cover the heater.
The instruction leaflet belongs to the appliance
and must be kept in a safe place. If changing
owners, the leaflet must be surrendered to the
new owner.
IMPORTANT: If the mains lead of this appliance is
damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualified person
in order to avoid a hazard.
WARNING: In order to avoid a hazard due to
inadvertent resetting of the thermal cut-out,
this appliance must not be supplied through an
external switching device, such as a timer, or
connected to a circuit that is regularly switched
on and off by the utility.
This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience or knowledge if they have been given
supervision or instruction concerning the use of
the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by children without supervision.
Children of less than 3 years should be kept away
unless continuously supervised. Children aged
from 3 years and less than 8 years shall only
switch on/off the appliance provided that it has
been placed or installed in its intended normal
operating position and they have been given
supervision or instruction concerning the use of
the appliance in a safe way and understand the
hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and
clean the appliance or perform user maintenance.
CAUTION: Some parts of this product can
become very hot and cause burns. Particular
attention has to be given where children and
vulnerable people are present.
Avoid use of an extension cord because the
extension cord may overheat and cause risk of
fire.
Ensure the PFH30R remote control unit is earthed.
Always disconnect the supply before working on the product.
Always ensure combustible materials such as drapes or
other furnishings are kept clear of the air inlet and air outlet.
This product should be mounted safely to a solid wall.
Ensure the supply cables are of adequate current carrying
capacity and are protected by a suitable fuse.
General
Thank you for purchasing this high power wall mounted fan heater.
Designed to provide heating for small commercial environments
such as garages and workshops.
The heaters work by gradually raising the air temperature in a
garage or workshop and should be positioned at head height
approximately (1.8m - 2.3m - see Fig. 2) where the controls can
reached.
The PFH30 and PFH30R heaters have an output of 3kW.
The angle the appliance is mounted at may be adjusted horizontally
and vertically - see Fig. 1 and Fig. 4.
Electrical
The installation of this appliance should be carried out by a
competent electrician and be in accordance with the current
IEE wiring regulations. The supply cable is not supplied with the
appliance.
Note: A suitable local isolating switch must be provided in the
electrical supply circuit as close as possible to the heater with at
least 3mm clearance on each pole.
Wall Mounting
Remove the screw (see 'z' in Fig. 3C) to remove the cover bracket.
Use the wall mounting bracket (see 'x' in Fig. 3A) as a guide to
mark off the hole positions on a suitable wall (a minimum height
of 1.8 metres is required from the floor level to the bottom hole of
the bracket - see Fig. 2). Solid brick or concrete block walls must
be drilled and plugged using the screws and wall plugs provided.
Fix the wall mounting bracket to the wall and slide the heater down
on to the bracket as shown in Fig. 3A.
Note: Ensure there is enough clearance above the wall mounting
bracket for the user to slide the heater onto the bracket.
The heater is held in place to the wall mounting bracket with 2
screws - see Fig. 3B.
Once electrical connections have been completed - see 'Electrical
Installation', re-attach the bracket cover (see 'y' in Fig. 3C) by
sliding into place and secure with the screw - see 'z' in Fig. 3C.
Pivot and rotate the heater into the desired position and tighten
the screw to secure - see 'w' in Fig. 4.

Electrical Installation

Before undertaking electrical installation, ensure the electricity
supply is disconnected from any relevant fixed wiring. With the
bracket cover removed proceed to feed the supply cord through
the cable entry at the bottom of the mounting bracket (drill knock-
out to suit).

Advertisement