Desa GWRP16A Safety Information And Installation Manual page 15

Unvented (vent-free) infrared gas heater
Table of Contents

Advertisement

OPERATING HEATER
Continued
TO SELECT
HEATING LEvEL
WARNING: When running
heater, set control knob at LOW,
MED or HI locked positions.
Never set control knob between
locked positions. Poor combus-
tion and higher levels of carbon
monoxide may result.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
MANUAL CONTROL MODELS
Slightly press in control knob and turn coun-
terclockwise
positions (see Figure 22).
IMPORTANT: Release downward pressure
while turning control knob. Control knob will
lock at the desired position.
Control Knob
Figure 22 - Burner Patterns for Manual
Control Models
THERMOSTAT MODELS
Turn thermostat control knob counterclock-
wise
to the desired heating level. The
main burner should light. Set control knob
to any heat level between 1 and 5 (see
Figure 23).
119346-01B
to the LOW, MED or HI
Burners
LOW
MED
HI
OFF
www.desatech.com
Control Knob
Figure 23 - Burner Patterns
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
PILOT position.
THERMOSTAT CONTROL
OPERATION
The thermostatic control used on these
models differs from standard thermostats.
Standard thermostats simply turn on and off
the burner. The thermostat used on this heater
senses the room temperature. At times the
room may exceed the set temperature. If so,
the burner will shut off. The burner will cycle
back on when room temperature drops below
the set temperature. The control knob can
be set to any heat level between 1 and 5. All
plaques will turn off and on.
Note: The thermostat sensing bulb mea-
sures the temperature of air near the heater
cabinet. This may not always agree with
room temperature (depending on housing
construction, installation location, room size,
open air temperatures, etc.) Frequent use of
your heater will let you determine your own
comfort levels.
MANUAL LIGHTING
PROCEDURE
1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 7 under Lighting
Instructions, page 14.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under Lighting Instructions, page 14.
5. Replace front panel.
Burners
to the
to the
15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents