Kenwood KDC-X679 Service Manual page 6

Cd receiver
Hide thumbs Also See for KDC-X679:
Table of Contents

Advertisement

KDC-X679
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
36
DSI
37
PM_MOT1
38
PM_MOT2
39
EPM
40
PM_OPEN
41
PM_CLOSE
42
PAN_RST
43
PM_DET
44
SC_CON
45
CD_DISC12_SW
46
CD_LOS_SW
47
CD_MUTE_R
48
CD_MUTE_L
49
CD_MRST
50
CD_MSTOP
51
CD_DISC8_SW
52
CD_LOE_LIM_SW
53
CD_LOEJ
54
CD_MOTOR
55
TUN_TYPE1
56
TUN_TYPE0
57
PON_ILL
58
PON_CD
59
PON
60
VCC2
61
COR_DET
62
VSS
63~65 TYPE_0~TYPE_2
66,67 NC
68
OPEL_DATA
69
OPEL_CLK
70
OPEL_CE
71
EXT_CONT
72
P_CON
6
Module
I/O
Application
EXTRA
I/O
(D) SI control terminal
P-MECHA
O
Panel motor control 1
P-MECHA
O
Panel motor control 2
I
FLASH EPM input terminal
P-MECHA
I
Panel full open detect
P-MECHA
I
Panel mechanism close detect
Panel µcom reset output
to PANEL O
P-MECHA
I
Panel mechanism detect
Between panel Communication control
to PANEL O
(FLASH CE)
CD
I
CD detect terminal (12cm)
CD
I
CD loading detect terminal
CD
I
CD MUTE (Rch) request terminal
CD
I
CD MUTE (Lch) request terminal
CD mechanism µcom RST terminal
CD
O
CD mechanism µcom stop terminal
CD
O
CD
I
CD detect terminal (8cm)
CD
I
CD detect terminal (chucking SW)
CD
I/O
CD motor control terminal
CD
O
CD motor control terminal
TUNER
I
Destination setting 1
TUNER
I
Destination setting 0
Power supply I/O
Key ILL power supply control
CD
O
CD WMA power supply control terminal
Power supply I/O
Power supply control
-
TYPE
I
E2PROM write request
-
TYPE
I
Destination switching
O
Not used
EXTRA
I/O
External display DATA
EXTRA
I/O
External display CLK
EXTRA
I/O
External display control request
EXTRA
O
External amp control
Power supply I/O
External amp control terminal
Truth Value
Processing Operation Description
Table
OFF : Hi-Z, Panel come off : Pulse driven,
ILL_ON and OPEN (Power_ON) : H
w
Refer to truth value table.
w
Refer to truth value table.
e
Refer to truth value table.
e
Refer to truth value table.
Normal : H, Reset, Momentary power down, Panel
is detached and 11 minutes after ACC_OFF : L
H : Function check
POWER OFF, ACC OFF : L
L : Rch mute request
L : Lch mute request
H : Normal, L : Reset
H : Mechanism µcom operation,
L : Mechanism µcom stop
H : Loading complete, L : No disk
i
Refer to truth value table.
i
Refer to truth value table.
t
Refer to truth value table.
t
Refer to truth value table.
ON : H, OFF : Hi-Z
CD : L, Other than CD : H, When RESET,
quicker than M-STOP L, Normal CD : NC
Power ON : H, Power OFF : Hi-Z
H : Write
y
Refer to truth value table.
Output : L
Not used
Not used
Not used
Power ON : H, Power OFF : Hi-Z, All OFF : Hi-Z

Advertisement

Table of Contents
loading

Table of Contents