Dell OptiPlex 9010 Owner's Manual page 50

Small form factor
Hide thumbs Also See for OptiPlex 9010:
Table of Contents

Advertisement

Error Message
Description
Decreasing available
One or more memory modules may be faulty or improperly seated. Re-install the memory
memory
modules and, if necessary, replace them.
Diskette drive 0 seek
A cable may be loose or the computer configuration information may not match the hardware
failure
configuration.
Diskette read failure
The floppy disk may be defective or a cable may be loose. If the drive access light turns on, try
a different disk.
Diskette subsystem
The floppy drive controller may be faulty.
reset failed
Gate A20 failure
One or more memory modules may be faulty or improperly seated. Reinstall the memory
modules and, if necessary, replace them.
General failure
The operating system is unable to carry out the command. This message is usually followed by
specific information—for example, Printer out of paper. Take the appropriate action to resolve
the problem.
Hard-disk drive
The hard drive failed initialization.
configuration error
Hard-disk drive
The hard drive failed initialization.
controller failure
Hard-disk drive
The hard drive failed initialization.
failure
Hard-disk drive read
The hard drive failed initialization.
failure
Invalid configuration
The computer configuration information does not match the hardware configuration.
information-please
run SETUP program
Invalid Memory
DIMM1 slot does not recognize a memory module. The module should be re-seated or
configuration, please
installed.
populate DIMM1
Keyboard failure
A cable or connector may be loose, or the keyboard or keyboard/mouse controller may be
faulty.
Memory address line
A memory module may be faulty or improperly seated. Reinstall the memory modules and, if
failure at address,
necessary, replace them.
read value expecting
value
Memory allocation
The software you are attempting to run is conflicting with the operating system, another
error
program, or a utility.
Memory data line
A memory module may be faulty or improperly seated. Reinstall the memory modules and, if
failure at address,
necessary, replace them.
read value expecting
value