  • Page 4: Operating Instructions

    OPERATING INSTRUCTIONS SLX45 MULTI-FUEL ® Wood GENERAL POINTS Only dry well seasoned wood should be burnt on this appliance as Before lighting the fire check with the installer that the work and burning wet unseasoned wood will give rise to heavy tar deposits.
  • Page 5: Door Operation

    MULTIFUEL GRATE This is normal and will cease after a short time. In the meantime the Your Charnwood is fitted with a multifuel grate which enables solid room should be kept well ventilated. Before relighting the fire, riddle, fuel, wood and peat to be burned equally effectively.
  • Page 6: Ash Clearance

    Some experimentation will be necessary to find the settings most To make ash removal easier there is a special Charnwood ash suitable for the particular fuel used and the draw on the chimney. To carrier available. This may be purchased from your supplier or, in revive the fire, empty the ashpans, riddle, and open the air controls case of difficulty, from ourselves.
  • Page 7: Special Points When Burning Coal

    OPERATING INSTRUCTIONS SLX45 MULTI-FUEL ® the summer,) then to prevent condensation, and hence corrosion, throat plate becomes tight between the faces this can cause it to fail the thermostat should be left at the maximum setting and the main prematurely.
  • Page 8: Trouble Shooting

    OPERATING INSTRUCTIONS SLX45 MULTI-FUEL ® Different types of sweep’s brushes are available to suit different Fume Emission flueways. For standard brick chimneys a wire centre sweep’s brush Warning Note: Properly installed, operated and maintained this fitted with a guide wheel is recommended. For prefabricated appliance will not emit fumes into the room.
  • Page 9: Co Alarm

    IF YOU NEED FURTHER HELP c) the door seals are in good condition. If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions. Your Local d) If the hot water goes cold when the pump is turned on, or if some...
  • Page 10: Installation Instructions

    PERFORMANCE CHIMNEY The rated outputs for the Charnwood SLX45 are shown in the Specification table. These outputs are obtained during the standard In order for the appliance to perform satisfactorily the chimney tests burning fuel with the doors closed over a 4 hourly re-fuelling height must not be less than 4 metres measured vertically from the interval for solid fuel and 1.5 hourly period for wood.
  • Page 11: Installation As An Inset Stove

    INSTALLATION INSTRUCTIONS SLX45 MULTI-FUEL ® Fig. 4. Performance Chart 1. INSTALLATION AS AN INSET STOVE 10.0 Boiler The SLX 45 is supplied with one of two panel packs that makes it Output (kW) either an Inset stove SLX45i or a Freestanding stove SLX45fs. The following sections apply specifically to the Inset Installation.
  • Page 12: Central Heating System

    INSTALLATION INSTRUCTIONS SLX45 MULTI-FUEL ® Fig. 6. Typical Central Heating & Hot Make two holes in the chimney breast, one in the front to give access Water System Using 4 Boiler Tappings for infilling and fixing the flue pipe, and one in the side to give access for the pipework.
  • Page 13: Fitting The Fire

    INSTALLATION INSTRUCTIONS SLX45 MULTI-FUEL ® return thermostat. that the flue pipe is central and then fill the space between the body of the appliance and the structural brickwork with vermiculite (e.g. We recommend fitting a pipe thermostat onto the gravity return pipe Micafil or similar) concrete.
  • Page 14 INSTALLATION INSTRUCTIONS SLX45 MULTI-FUEL ® shown in Figs. 10 & 11 and may be either on a freestanding hearth or between the vertical and the sleeve/fluepipe must be not less than in an ‘Inglenook’ type f ireplace. In these configurations the minimum 135°.
  • Page 15: Thermostat

    INSTALLATION INSTRUCTIONS SLX45 MULTI-FUEL ® fluepipe from the stove will protrude a small amount through the 2. The plates round the sides and back of the grate must be in hole in the register plate, and will be sealed in position. This is shown position and sitting correctly.
  • Page 16: Dimensions

    SLX45 DIMENSIONS (MM) SLX45 MULTI-FUEL ® 2 Boiler tappings each side 1” B.S.P. Female. ø168 Flue Centre Line Height to Top of Flue Ring...
  • Page 17: Parts Lists

    ** These items are included in the Freestanding Panel Pack the manufacturer at the address shown. This drawing is for identification purposes only. charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...
  • Page 18: Certification

    A.J WELLS & SONS LTD A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 BSEN 13229:2001 EN13240:2001 SLX45 MKII MULTI-FUEL ROOMHEATER & BOILER FIRED BY SOLID FUEL EC Certificate of conformity no: KV080-CPD-2011 Maximum operating pressure:...
  • Page 20 BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 7 7 •...