Advertisement

Quick Links

CHARNWOOD SLX45
Multi-Fuel
Roomheater with Boiler
Operating
and

Installation Instructions

®
C H A R N W O O D
B i s h o p s W a y , N e w p o r t , I s l e o f W i g h t P O 3 0 5 W S , U n i t e d K i n g d o m
T : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 9 9
F : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 8 8
c h a r n w o o d @ a j w e l l s . c o . u k
w w w . c h a r n w o o d . c o m
A D i v i s i o n o f A . J . W e l l s & S o n s L i m i t e d R e g i s t e r e d i n E n g l a n d N o . 0 3 8 0 9 3 7 1

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood SLX45

  • Page 1: Installation Instructions

    CHARNWOOD SLX45 Multi-Fuel Roomheater with Boiler Operating Installation Instructions ® C H A R N W O O D B i s h o p s W a y , N e w p o r t , I s l e o f W i g h t P O 3 0 5 W S , U n i t e d K i n g d o m...
  • Page 3: General Points

    OPERATING INSTRUCTIONS FOR THE CHARNWOOD SLX45 better than soft wood. Burning wet unseasoned wood will GENERAL POINTS also result in considerably reduced outputs. The wood should be cut and split and then left to season in a well Before lighting the fire check with the installer that the...
  • Page 4: Controlling The Fire

    To make ash removal easier there is a special Charnwood shown in Fig. 1. This is linked to a thermostat which ash carrier available. This may be purchased from your controls the boiler temperature.
  • Page 5: Overnight Burning

    RIDDLING The throat plate and flueways may be cleaned with a low fire still burning. Use the scraper tool to scrape any sooty Riddling twice a day is usually sufficient. deposits off the front of the plate until they fall into the fire. Also scrape any soot deposits from the sides and top of the The fire should be riddled with all doors shut.
  • Page 6: Chimney Sweeping

    Fire Blazing Out Of Control. working well. After long periods where the fire has been out of use, the Check that: chimney and appliance flueways should be cleaned before a) the doors are tightly closed, lighting. b) the thermostat knob is turned down to the minimum setting, Door Seals c) the air inlet damper is closed (at the bottom left of the...
  • Page 7 flueways should then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately. After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought if necessary.
  • Page 8: Health And Safety Precautions

    PERFORMANCE Boiler Output (kW) The rated output for the Charnwood SLX is 9.4 kW (32,000 btu/h) to water and 3.5 kW (11,900 btu/h) to 12.0 the room. These are the outputs obtained during the standard test 10.0...
  • Page 9: Preparation Of Fireplace

    HEARTH inhibitor should be used. The system must be correctly vented as shown in Figs. 6 and 7. The height differential The appliance must be installed on a fireproof hearth and between the header tank and the appliance must not must be situated at least 300 mm (12 inches) from any exceed 15.2 metres (50 feet).
  • Page 10: Flue Connection And Infilling

    that it is central and that a good seal is made between the sealing flange 22mm Open Vents Feed and Expansion Tank and the face of the surround. Cold Water Tank Remove any excess fire cement from Overflow Overflow around the sealing flange. The fire should be screwed to the Domestic Hot Water Draw Off hearth through the holes at the base...
  • Page 11: Pre Lighting Check

    PRE LIGHTING CHECK Before initial lighting check the following points: Flaunching 1. The bottom grate bars must all be fitted and should Short Length move freely and easily when the riddling mechanism is Of Flue Pipe, operated. or Flue Offset. 2.
  • Page 12 2 Boiler tappings each side 1” B.S.P. Female. ø168 Charnwood SLX Dimensions (all dimensions are in mm) Page 12 SLX 09.00...
  • Page 13: Parts List

    Issue B Charnwood SLX45 Parts List 20 21 Item Part Description Item Part Description 008/KV35S Door Seal Set Inc. Adhesive 003/TV02/## R.H. Door 008/FW29 Door Seal Adhesive 009/SLX45/A Replacement Firebox/Boiler Assy. 006/KV18 Glass Inc. Glass Channel 012/KV12 Serial No. Label...