charnwood
Operating & Installation Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Charnwood LA 45

  • Page 1 ® charnwood Operating & Installation Instructions...
  • Page 3: Table Of Contents

    C O N T E N T S O P E R AT I N G I N S T R U C T I O N S Fuel Door Operation Grate Lighting Controlling the Fire Riddling Refuelling Ash Clearance Overnight Burning Cleaing and Maintenance Throat Plate and Flueway Cleaning...
  • Page 4: Operating Instructions

    For instructions on burning other fuels please ask your supplier or Housing Authority for the "Charnwood Instruction Supplement"?. PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE, ITS USE WILL INVALIDATE THE...
  • Page 5: Riddling

    The more reactive fuels, like Homefire, will burn To make ash removal easier there is a special Charnwood ash better when the doors are open than fuels like Phurnacite, carrier available.
  • Page 6: Overnight Burning

    OPERATING INSTRUCTIONS ® Fig. 3. Grate Operation the front fire bars or damage to the glass may be caused when the doors are closed. OVERNIGHT BURNING Empty the ashpan, if necessary, and then riddle the fire. If the fire is very low then it may be necessary to add a little fuel and turn the thermostat control up to maximum for a brief period until the fire is burning brightly before filling with fuel.
  • Page 7: Chimney Sweeping

    OPERATING INSTRUCTIONS ® The appliance is finished in vitreous enamel. To clean the horizontal surfaces after sweeping. surfaces simply wipe over with a dry cloth. Abrasive pads and In situations where it is not possible to sweep through the...
  • Page 8 OPERATING INSTRUCTIONS ® If the fire is over-fired it will cause premature failure of the b) the throat plate is fitted correctly (see Fig. 4.) and that it is internal fire parts. Overfiring is occurring when any internal not distorted.
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS ® Fig. 5. Performance Chart HEALTH AND SAFETY PRECAUTIONS Please take care when installing the appliance that the Boiler Output requirements of the Health and Safety at Work Act 1974 are (kW) met. Some types of fire cement are caustic and should not be 12.0...
  • Page 10: Central Heating Sytem

    INSTALLATION INSTRUCTIONS ® access for infilling and fixing the flue pipe, and one in the side HEARTH to give access for the pipework. The appliance must be installed on a fireproof hearth and must be situated at least 300 mm (12 inches) from any combustible CENTRAL HEATING SYSTEM material.
  • Page 11: Fitting The Fire

    INSTALLATION INSTRUCTIONS ® Fig. 8. Typical Central Heating & Hot forming on the boiler faces and will thereby increase the life Water System Using 4 Boiler Tappings of the boiler. It will also ensure that priority is given to the domestic hot water.
  • Page 12: Thermostat

    INSTALLATION INSTRUCTIONS ® Fig. 11. Typical Installation ASSEMBLY Fit the side panels and hood onto the appliance. Instructions Flaunching for this are enclosed with the panel pack. Short Length Replace any internal parts previously removed. Of Flue Pipe, or Flue Offset.
  • Page 13 COUNTRY 4 DIMENSIONS (MM) LA 45 & 50IB DIMENSIONS (MM) ® ® 168 i/d (To suit 150mm flue pipe) Boiler tappings are 1" BSP Female. (2 Each side)
  • Page 14 Prices are correct at the date shown above but may be subject to change without notice. charnwood charnwood BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T:+4 4 (0)1983 537799 • F:+4 4 (0)1983 537788 • SPARES@CHARNWOOD.COM • WWW.CHARNWOOD.COM ®...