Maintenance - Porter-Cable 725 Porta-Band Instruction Manual

Two-speed porta-band band saw
Hide thumbs Also See for 725 Porta-Band:
Table of Contents

Advertisement

KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. All plastic parts
should be cleaned with a soft damp cloth. NEVER use solvents to clean plastic
parts. They could possibly dissolve or otherwise damage the material.
Wear ANSI Z87.1 safety glasses while using compressed air.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord plug are
making good contact in the outlet. Also, check for blown fuses or open circuit
breakers in the line.
LUBRICATION
Although all PORTER-CABLE tools have been thoroughly lubricated with a
sufficient amount of high grade lubricant at the time of manufacture, it is
recommended that the oil level in the gear chamber be checked before using
your saw and periodically thereafter as follows:
1.
WARNING: Remove band saw blade to prevent accidental contact.
2.
Remove oil filler plug and gasket (A) Fig. 7.
3.
Stand saw on front pulley housing and start motor.
4.
With motor running, observe whether the lubricant is being carried over
the top of the worm gear teeth (B) Fig. 7. If not, stop the motor and add a
small amount of lubricant furnished with your saw.
5.
Repeat step 4 until the lubricant is carried over the top of the worm gear
teeth while the motor is running. DO NOT OVERFILL GEAR CHAMBER. If you
do, the pressure created by the pumping action of the gears will force
lubricant thru the seals into the motor chamber and may cause damage to
the motor as well as gear failure.
6. Install oil plug and gasket.

MAINTENANCE

A
B
Fig. 7