Model 13360 and 13361

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical
information that is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or
to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics
product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

General Information

The Model 13360 and 13361 Clean Room Speakers are
designed to provide outstanding voice reproduction for
use in public address and general alarm applications in
clean room environments.
The units can be ceiling-mounted or flush-mounted into
a wall. The smooth front panel is sealed with a
polyester overlay that allows for wash-downs while
keeping the speaker particulate-free. The back box is
fabricated from stainless steel. The Model 13360 has an
8-ohm impedance, and the Model 13361 has a 70 V
line-matching transformer.
The speakers' graphic overlay is designed to withstand
exposure to many chemicals. See a partial listing
below:
Ajax/Vim in solution
1
Alkalicarbonate solution
Ammonia (<40%)
Acetic Acid (50%)
1
Ariel powder in solution
1
Bleach
Castor oil
Caustic soda (<40%)
Cutting oil
Cylohexanol
Diacetone alcohol
Diesel
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
V
ISIT WWW
G A I - T R O N I C S ® C O R P O R A T I O N
A H U B B E L L C O M P A N Y
Clean Room Speakers
1
Downey/Lenor
Ethanol
Glycerine
Glycol
1
Gumption
Hydrochloric acid (<36.7%)
Hydrogen Peroxide (25% solution)
Linseed Oil
Methanol
Nitric Acid (<10%)
Paraffin oil
Persil powder in solution
610-777-1374  800-492-1212  Fax: 610-796-5954
.
-
.
GAI
TRONICS
COM FOR PRODUCT LITERATURE AND MANUALS
Clean Room Speaker Outline Drawing
Petroleum spirit
Phosphoric acid (<30%)
Potassium ferricyanide
Potassium hydroxide (<30%)
Pure terpentine
1
SBP 60/95
Sulfuric acid (<10%)
Tomato Ketchup
Trichloroacetic acid (<50%)
White spirit
1
Windex
1
Wisk
Pub. 42004-361F
1

Advertisement

loading

Summary of Contents for GAI-Tronics 13360

  • Page 1: Confidentiality Notice

    GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
  • Page 2: Installation

    Pub. 42004-361F Model 13360 and 13361 Clean Room Speakers Page 2 of 4 Installation The dimensions for the cut-out for the ceiling or wall mounting are provided below. The back box depth is 3.5 inches. Figure 1. Wall or Ceiling Cut-out Dimensions f:\standard ioms - current release\42004 instr.
  • Page 3 Model 13360 and 13361 Clean Room Speakers Page 3 of 4 Wiring Please refer to the typical wiring configurations for the Model 13361 (Figure 2) and Model 13360 Clean Room Speaker (Figure 3) shown below: Figure 2. Typical wiring configuration for Model 13361 Clean Room Speaker Figure 3.
  • Page 4: Specifications

    Front panel ................8 mil polyester over 16-gauge stainless steel Back box/Mounting bracket ................16-gauge stainless steel Shipping weight & dimensions Model 13360 ................... 11.00 lbs., 17.00 17.00  11.00 inches Model 13361 ................... 11.75 lbs., 17.00 17.00  11.00 inches Environmental Operating temperature ................
  • Page 5: Warranty

    Warranty Equipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that any GAI-Tronics equipment supplied hereunder shall be free of defects in material and workmanship, shall comply with the then-current product specifications and product literature, and if applicable, shall be fit for the purpose specified in the agreed-upon quotation or proposal document.