XX155-01-00 16-channel Digital Video Servers Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
20. Replacement Parts - Use only Vicon specified replacement parts or an approved equivalent to prevent unit damage and injury. 6. Attachments - Use only Vicon recommended attachments to prevent unit damage and personal injury.
Warning: Power must be removed from this unit before removing circuit modules or ribbon cables. Caution: This unit contains circuit cards with integrated circuit devices that can be damaged by static discharge. Take all necessary precautions to prevent static discharge. iv • FCC Notice XX155-01-00 Rev 1105 Kollector Network Server...
This manual is delivered subject to the following conditions and restrictions: • This manual contains proprietary information belonging to Vicon. Such information is supplied solely for the purpose of assisting explicitly and properly authorized users of the ViconNet system. •...
Kollector Network Server. • Chapter 4, Operation, describes how to power on, boot and power off the Kollector Network Server. • Chapter 5, Troubleshooting, provides information on what to do in the unlikely event of a Kollector Network Server malfunction.
Front Panel Controls and Connections......................5 Rear Panel Controls and Connections ......................6 Mounting .................................7 Desktop.................................7 Rack................................7 Installing the Kollector Network Server .......................7 Step 1: Connecting the Hardware.........................8 Step 2: Connecting External Hardware to Termination Boxes ..............9 Step 3: Connecting the Power Supply......................10 CHAPTER 4 OPERATION....................11 About This Chapter ............................11...
Page 8
Cable Types ..............................18 CHAPTER 10 TECHNICAL INFORMATION ..............19 VICON STANDARD EQUIPMENT WARRANTY..............22 List of Figures Figure 2-1: Kollector Network Server Quick Installation ..................3 Figure 3-1: Front Panel Layout ........................... 5 Figure 3-2: Rear Panel Layout..........................6 Figure 3-3: Looping Cable........................... 8 Figure 3-4: Inline Resistor ..........................
The Kollector Network Server (KN) is a 16-channel digital video server powered by a software platform called ViconNet. This platform allows each KN server to record and transmit video to other Kollector Elite recorders and ViconNet workstations over the network.
Used to open front security door on KN Server. Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier’s responsibility to provide suitable delivery. Inspect the cartons upon delivery and, if damage is present, make detailed notes on the carrier’s bill. Then, obtain the carrier agent’s signature and file a damage claim as soon as possible.
Installation For novice or first-time installers, these steps provide the most thorough and accurate instructions. About This Chapter This chapter details the complete installation of the Kollector Network Server. The following sections provide information as follows: • Unpacking the Server defines how to remove the unit and accessories from the box.
This section describes the Kollector Network Server unit's front and rear panels. Front Panel Controls and Connections The following picture shows the Kollector Network Server front panel. Each panel component is described in the table below. Figure 3-1: Front Panel Layout The Kollector Network Server's front panel contains the following components: •...
Rear Panel Controls and Connections The following picture shows the Kollector Network Server rear panel. Each panel component is described below. Figure 3-2: Rear Panel Layout The Kollector Network Server's rear panel contains the following components: • Power Switch: Used to power on and off the power supply of the recorder.
There are two types of mounting recommended for the server, either desktop or rack. Desktop The desk or table must provide a surface of suitable strength for the Kollector Network Server’s weight of 26 lb (11.8 kg). In addition, there must be area left around the cabinet to provide suitable airflow for cooling.
230VAC power, it will be necessary to obtain a suitable power cord for use. This cable is a standard computer 230 VAC power cord. 9. Connect the remaining power cable to the UPS unit. 8 • Installation XX155-01-00 Rev 1105 Kollector Network Server...
3. Install the other end of this cable into the device it will communicate with; for example, a Camera Dome or other type of receiver. Sensor Input When using wire connectors to connect devices to the Kollector Network Server, refer to the guidelines described below, according to the specific device type. To connect a sensor to the Kollector Network Server: 1.
Figure 3-4: Inline Resistor Step 3: Connecting the Power Supply To ensure that the Kollector Network Server is protected during a power failure and that no important data is lost, it must be connected to an uninterruptible power source (UPS) before use.
Operation About This Chapter This chapter details power on, booting and power off of the Kollector Network Server. For full programming and operation information, refer to the Kollector Network Server Software manual, XX155-30-00. The following sections provide information as follows: •...
• If the recorder boots, but does not display the Main Screen, reboot the unit by toggling the front panel power switch OFF and ON. If the recorder still fails to boot, call Vicon Technical Support. 12 • Troubleshooting XX155-01-00 Rev 1105 Kollector Network Server...
2. Open the filter housing on the left-hand side. 3. Carefully remove the old filter, and then wash it under running water with a mild soap. 4. When the filter is completely dry, return it to its place in the Kollector Network Server. 5. Close the filter housing.
Page 22
2. Carefully remove the filter, look at the front fan and ensure it is operating properly. 3. Look at the fan in the rear of the Kollector Network Server and ensure it is operational. 4. When you have finished, replace the filter, and then close the filter housing.
Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
Let the required picture quality and cable distance provide a guide in choosing the best cable type. For cables other than the approved Vicon types below, contact the manufacturers listed below. Note that “BC” refers to bare copper and “TC” refers to tinned copper.
Chapter 9 Twisted-Pair Cable Recommendations CAUTION: Careful selection of the proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended are installed. Materials Use a pure copper stranded conductor with or without a tin plating to obtain a low DC resistance. Do not use cable with either a steel or an aluminum stranded conductor because these do not transfer signals effectively for long distances.
Input Voltage 120 - 230 VAC ±10%, 50/60 Hz nominal. NOTE: Vicon requires the use of uninterruptible power supply systems (UPS) to prevent voltage fluctuations that can affect operation and cause damage to the equipment. Failure to comply with this violates the unit warranty.
Page 28
Shipping Length: 23.5 in. (597 mm) Dimensions Width: 21 in. (533 mm) Height: 9 in. (229 mm) Shipping Weight Approximately 36 lb (16.3 kg) Shipping Volume 4.75 ft (0.13 m 20 • Technical Information XX155-01-00 Rev 1105 Kollector Network Server...
Page 29
Maximum Room 50 to 86° F (10 to 30° C) Temperature Range Storage -4 to 158° F (-20 to 70° C) Temperature Range Storage Humidity 0 to 95% relative, non-condensing Range Technical Information • 21 XX155-01-00 Rev 1105 Kollector Network Server...