Vicon ViconNet Nucleus Installation & Configuration Manual

Advertisement

Installation & Configuration Guide
XX239-00-00
ViconNet Nucleus
Vicon Industries Inc., 89 Arkay Drive, Hauppauge, New York 11788
Tel: 631-952-2288 Fax: 631-951-2288 Toll Free: 800-645-9116
24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300
Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the
operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed
to be used in life-critical situations and must not be used for this purpose.
www.vicon-security.com
Document Number: 8009-8239-00-00
Issued: 711
Product specifications subject to change without notice.
Copyright © 2011 Vicon Industries Inc. All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ViconNet Nucleus and is the answer not in the manual?

Questions and answers

Summary of Contents for Vicon ViconNet Nucleus

  • Page 1 24-Hour Technical Support: 800-34-VICON (800-348-4266) UK: 44/(0) 1489-566300 Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be entirely error free or perform precisely as described in the documentation. This system has not been designed to be used in life-critical situations and must not be used for this purpose.
  • Page 2: Table Of Contents

    23   Technical Information Vicon, ViconNet, and their logos are registered trademarks of Vicon Industries Inc. Windows is a registered trademark of Microsoft Corporation. Other company and brand products and service names are trademarks or registered trademarks of their respective holders...
  • Page 3: General

    ViconNet Nucleus Installation and Configuration Guide General This manual provides information for installing the ViconNet standalone Nucleus preinstalled on a PC. It is available as a rack-mount unit, VN-NUC- SYSTEM-R, but will also be available as a tower if required, VN-NUC- SYSTEM.
  • Page 4: Hardware Installation

    The rack-mount model, VN-NUC-SYSTEM-R is a 1 RU unit; the VN-NUC- SYSTEM is a desk-top unit. These units meet requirements for an FCC Class A computing device and CE Vicon requires the use of line conditioners, voltage regulators and uninterruptible power supply (UPS) systems in the electrical power service. Note Read all instructions before beginning the installation.
  • Page 5: Unpacking And Inspection

    ViconNet Nucleus Installation and Configuration Guide Unpacking and Inspection All Vicon equipment is tested and inspected before leaving the factory. It is the carrier’s responsibility to provide suitable delivery. Inspect the cartons upon delivery and, if damage is present, make detailed notes on the carrier’s bill.
  • Page 6: Unit Components

    ViconNet Nucleus Installation and Configuration Guide Unit Components This section describes the VN-NYC-SYSTEM-R front and rear panels. Front Panel Controls and Connections • Power Switch: Used to power on the unit. • Power LED Indicator: Blue LED used to display the power status (ON means unit on and OFF means unit off).
  • Page 7: Mounting

    ViconNet Nucleus Installation and Configuration Guide • Mouse Port: USB connector used to connect the provided optical mouse (included). • USB Connectors: Used for optional devices (4). • Network Port: RJ-45 connectors; use to connect to a LAN/WAN (100/1000 Base T).
  • Page 8: Installing The Vn-Nuc-System

    ViconNet Nucleus Installation and Configuration Guide Installing the VN-NUC-SYSTEM After the unit is mounted permanently, follow the steps in this section to install the hardware. • Step 1: Connecting the Hardware, below • Step 2: Connecting the Power Supply Important Notes The connection of external hardware may require simple hand tools.
  • Page 9 ViconNet Nucleus Installation and Configuration Guide Step 2: Connecting the Power Supply To ensure that the unit is protected during a power failure and that no important data is lost, it must be connected to an uninterruptible power source (UPS) before use.
  • Page 10: Operation

    ViconNet Nucleus Installation and Configuration Guide Operation Powering On the Unit To power on the system: With the unit set up as shown in Installation, open the front panel cabinet and press the front panel pushbutton Power Switch. The button does not lock into position;...
  • Page 11: Using The Viconnet Application

    ViconNet Nucleus Installation and Configuration Guide Using ViconNet Accessing the Configuration Functions The configuration functions are performed via the System Settings window applicable to a selected site. This unit will be configured to be the Nucleus of the system. To access the System Settings window: 1.
  • Page 12 ViconNet Nucleus Installation and Configuration Guide 2. Select the site for which you want to configure the network setup and click . The System Settings window is displayed. Note The VN-NUC-SYSTEM can configure all sites in the network. The System Settings window has the following options: When the function is not supported, the associated button is disabled (grayed out).
  • Page 13: Registering Your System

    ViconNet Nucleus Installation and Configuration Guide Note The Site Name and Site IP information are displayed automatically on this and subsequent windows. Registering Your Unit The full functionality of the VN-NUC-SYSTEM is available only after it is registered. Before the registration procedure is performed, it will function with limited "Viewer"...
  • Page 14: Modifying The System Configuration

    You will need these to complete registration. Note Licensing is done through Vicon’s website. On www.vicon-security.com, go to the Support tab and select Software Registration and follow those instructions. Be sure to have the License ID and password that is on the label of the software CD jewel case.
  • Page 15 ViconNet Nucleus Installation and Configuration Guide configured only on the master Nucleus device. Refer to instruction manual XX231 for details on configuring the backup Nucleus. Notes If the Nucleus fails, any device that uses that master Nucleus will automatically shift to local operation mode. This means that it will use the latest Nucleus configuration from before losing the Nucleus and will keep operating without a Nucleus.
  • Page 16 ViconNet Nucleus Installation and Configuration Guide Creating a New Network This procedure provides a five-step example of how to create a new ViconNet network using a field-proven method of setup and commissioning. In this example, we will create a network made up of a number of sites.
  • Page 17 ViconNet Nucleus Installation and Configuration Guide 3. Click . The Network Settings window is displayed. 4. You can change the device's name, if required, by clicking open the Change Name window. After you have assigned a new name to the site, click .
  • Page 18 ViconNet Nucleus Installation and Configuration Guide 8. Click . The application will reboot. Step 2: Configuring the Network Setup for a Master Nucleus System The ViconNet system enables you to configure this Workstation to function as the master Nucleus in the system.
  • Page 19 ViconNet Nucleus Installation and Configuration Guide Step 3: Configuring a Site to Connect to Nucleus Follow the procedure below to connect a site to the Nucleus. 1. Go to the site you want to setup and follow steps 1 through 3 in Step 1: Setting the Site’s IP Address.
  • Page 20 ViconNet Nucleus Installation and Configuration Guide Step 5: Testing the Network In this final step, you will carry out a number of operational tests to ensure that the network has been setup properly. 1. In the Main window, ensure that all sites appear in the Site List when they come online and that you can select a camera from each site by clicking on 2.
  • Page 21 ViconNet Nucleus Installation and Configuration Guide 4. Go to the site handling the master Nucleus and drag a camera from the Site List to check if video can be seen from a site on the Nucleus. 5. Go to the site and playback a camera. The site should appear in the Site List.
  • Page 22: Shipping Instructions

    Shipping Instructions Use the following procedure when returning a unit to the factory: 1. Call or write Vicon for a Return Authorization (R.A.) at one of the locations listed below. Record the name of the Vicon employee who issued the R.A.
  • Page 23: Technical Information

    Electrical Characteristics Input Voltage 115 - 230 VAC ±10%, 50/60 Hz nominal. NOTE: Vicon requires the use of uninterruptible power supply systems (UPS) to prevent voltage fluctuations that can affect operation and cause damage to the equipment. Failure to comply with this violates the unit warranty.
  • Page 24 ViconNet Nucleus Installation and Configuration Guide Mechanical Characteristics Application Indoor Mounting Desktop or standard 19 in. (483 mm) rack mount and stackable, 1 RU height Dimensions VN-NUC-SYSTEM-R Rack-Mount Unit: Height (H): 1.75 in. (44.45 mm) Width (W): 19.0 in. (483 mm) with racking ears;...
  • Page 25 Vicon Security Management Systems (SMS) All Models: All hardware is warranted for two years from date of original retail purchase. 10. Any product sold as “special” or not listed in Vicon’s commercial price list: One year from date of original retail purchase.
  • Page 26 Vicon Industries Inc. Corporate Headquarters 89 Arkay Drive Hauppauge, New York 11788 631-952-2288 800-645-9116 Fax: 631-951-2288 Vicon Europe Headquarters Brunel Way Fareham, PO15 5TX United Kingdom +44 (0) 1489 566300 Fax: +44 (0) 1489 566322 Vicon Germany Kornstieg 3 D-24537 Neumuenster...