Page 1
Illustration selon la version Read this instruction manual carefully before Imágene según versión first operation and strictly observe the safety Figurre a seconda del modello regulations! Afbeelding afhankelijk van de uitvoering 9 416 102 english 01/2008...
Page 2
SOLO dealer or get in touch Pump switched off with our service department directly. Pump switched on, high operating pressure, approx.2.8 bar...
Page 3
Index Page 1. Safety regulations ......................4 Correct use General safety instructions Safe handling of spray pesticides Safe handling of the rechargeable battery and the charger Work clothing Transportation of the device Before and during work Maintenance and repairs 2. Specification / special accessories .................7 3.
Safety regulations 1. Safety regulations 1.1 Correct use • This backpack sprayer must only be used for the purpose of applying approved liquid pesticides, insecticides, weed killer (herbicides) and liquid fertilizers available from authorised specialist dealers. • Observe all instructions provided by the pesticide manufacturer. •...
Page 5
Always hold the body of the plug when plugging it in and disconnecting it. Never pull it out by the cable. • The charger is only designed to recharge the rechargeable battery that is supplied by SOLO for this backpack sprayer. Ensure that the battery is always correctly connected to the charger before charging.
Safety regulations 1.5 Work clothing Always wear suitable protective clothing in accordance with the relevant regulations. The clothing must protect all parts of your body against contact with pesticides and against objects that are kicked up – i.e. protective gloves, face protection (e.g. protective goggles), protective footwear, body protection –...
Page 7
Standard battery 5 Ah Approx. 5 Upgrade battery 7.2 Ah Approx. 7 Fuse Glass fuse, 5x20 mm, 4A SOLO part no.: 00 84 055 Possible operating time per charging cycle With standard battery 5 Ah Setting I approx. 5.5 Setting II approx.
Standard delivery, Operating / functional components 3. Standard delivery • Standard device with hand valve pre-assembled on the high-pressure hose • Spray tube with pre-assembled nozzle attachment • Charger with mains cable / EURO plug and 3 mains plug adapters for different countries •...
Page 9
Operating / functional components View: top, solution tank opened View: right hand side, lower part View: protective housing opened Charger and mains outlet adapter ENGLISH 9...
Preparing the unit for use 5. Preparing the unit for use Check that the double plugs are securely connected and that polarity is correct. 5.1 Assembly Close the protective casing and twist the locking buttons back in a clockwise direction The backpack sprayer with rechargeable until they are horizontal.
Page 11
Preparing the unit for use 5.3 Adjusting the carrying straps Clip the carrying straps into the clips (6) on both sides and lift the backpack across your shoulders. Use the sliding clips, adjust the shoulder straps to the right length. Fit the bottom strap around the midriff of the wearer and close the clip, again using the sliding clips to adjust the length of the straps...
Page 12
Mixing solutions and filling the solution tank 6. Mixing solutions and filling the After filling, firmly close the screw cap on the filling opening to prevent any solution from solution tank escaping. When handling the substances for spraying, always follow the safety Required volumes of spraying solution instructions printed at the start of these Mix the solutions in accordance with the...
We Setting I 0,44 recommend the use of the special SOLO cleaner for pesticide sprayers that is available Setting II 0,56 in 500 ml bottles. Part no.: 4900600...
Page 14
Using the backpack sprayer 7.3 Spraying The red clip can be used to secure the hand valve in its rest position to prevent accidental Ensure that you follow all of the safety spraying. instructions when using the backpack sprayer. Never use the sprayer under windy conditions or if it is raining, as this would risk widespread drifting of the spraying agent.
Page 15
8.4 Replacing the fuse Replacement glass fuses (5x20 mm 4A) are available to order from your local SOLO dealer under the part no. 0084055. To replace the fuse, release the fuse holder (14) with a screwdriver (turn it half a turn anti- clockwise) and then pull it out.
We recommend the use of the special SOLO cleaner for pesticide sprayers that is available in 500 ml dosing bottles. Part no.: 4900600...
Page 17
Warranty, Wearing parts 9. Warranty 10. Wearing parts The manufacturer guarantees problem free Various parts are subject to application-specific quality and will cover the cost of replacing wear or to normal wear and must be replaced parts which are found to be faulty in material or in good time if necessary.
Made in Germany SOLO SOLO Postfach 60 01 52 P.O.Box 60 01 52 D 71050 Sindelfingen D 71050 Sindelfingen Germany Tel. 07031-301-0 Phone+49-7031-301-0 Fax 07031-301-130 +49-7031-301-149 info@solo-germany.com export@solo-germany.com...
Need help?
Do you have a question about the AccuPower 416 and is the answer not in the manual?