Download Print this page

Panasonic WV-Q122E Operating Instructions Manual page 6

Wall mount bracket

Advertisement

6. Disassembly of Camera
(1) Remove the upper base from the camera by
loosening 3 screws. The screws that are
removed need to be used during reassembly. Be
careful to not lose them. Turn the upper base
and separate it.
* Special screw (mounting screw): Use a hexa-
gon wrench for the hexagon screw (M6).
(2) Remove the attachment pipe from the upper
base by loosening 4 screws.
* Special screw (mounting screw): Use a hexa-
gon wrench for the hexagon screw (M6).
7. Setting Switches
Refer to DIP SWITCH SETTINGS in the manual
included with the camera.
8. Cable Connection
Refer to CONNECTIONS in the manual included
with the camera.
Warning: Seal the cables with plastic or rubber
tape to prevent it from being exposed.
9. Mounting Upper Base
Fix the upper base to the bracket.
• Fasten 4 screws (the screws that were removed in
step (2) of "6. Disassembly of Camera") making
sure that "REAR" engraved on the upper base faces
the wall.
10. Mounting Camera
(1) Aim the START arrow at the bent portion of the
leaf spring on top of the camera.
(2) Be sure to hook the fall prevention wire to the
bracket.
(3) Fix the camera to the upper base.
• Move the camera up so that its guide pins fit into
the guide holes of the upper base.
• Turn the camera counter-clockwise to the end,
viewed from the bottom.
• Fasten 3 screws (the screws that were removed
in step (1) of "6. Disassembly of Camera").
Caution: Tighten the three (3) mounting screws for
the upper base.
Recommended torque: Approximately 2.45 N/m
{24 kgf cm}
Poorly tightened screws may result in water
leaking into the camera or possible fire.
x3
Bending
x3
-6-
Upper Base
Attachment Pipe
Camera
Camera Fixing Screw
x4
Upper Base
Leaf Spring
Fall Prevention Wire
Upper Base
Camera
x4

Advertisement

loading