DC VOLTS
Range Resolution
200mV
2V
20V
500V
Input impedance: 10MΩ for all ranges.
RESISTANCE (OHMS)
Range Resolution
200Ω
2KΩ
200KΩ
20M Ω
DIODE/CONTINUITY TEST
Function
Diode test
Continuity
test
DC AMPS
Range Resolution
2mA
20mA
200mA
10A
Measuring time is equal to or less than 15 seconds and time
interval is equal to or over 15 minutes.
E
Accuracy
100µV
1mV
±(0.8% of reading
+ 5 digits)
10mV
1V
Accuracy
0.1Ω
±(1% of reading
1Ω
+ 5 digits)
10Ω
10K Ω
±(2% of reading
+ 5 digits)
Range Resolution
Accuracy
1mV
Displays,
voltage drop
approximation
1Ω
50Ω or less,
buzzer (beeper)
will sound
Accuracy
1µA
±(1.5% of reading 0.315A/250V fuse
10µA
+ 5 digits)
100µA
10µA
±(2% of reading
+ 5 digits)
Overload
Protection
500V DC
or AC
500V RMS
Overload
Protection
250V DC/AC RMS
Overload
Protection
250V
DC/AC
RMS
Overload
Protection
Non-Protected