Section 4 − Specifications; Serial Number And Rating Label Location; Unit Specifications - Hobart AirForce 700i Owner's Manual

Welding system & torch
Hide thumbs Also See for AirForce 700i:
Table of Contents

Advertisement

4-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Unit Specifications

Power Supply
Input
Rated AC phase (PH) and line frequency (Hz)
Rated Input Voltage (U
) and rated Input
1
Current (I
) and I
eff at rated output. I
1
1
to determine power cord rating
Power Factor/KVA/KW at Rated Output
Peak KW at Arc Stretch
Output
Rated Open Circuit Voltage (U0) Type
Output Characteristic
Output Current Range
Output Current and Voltage Rating at Rated
Input Voltage (I
and U
at U
2
2
1
Duty Cycle at 1045 F (405 C) at rated conditions
(U
, I
, U
, I
) based on a 10 minute period
1
1
2
2
General
Operating Temperature
IP Code − Degree of protection provided by
enclosure
Toppling or tilting
Gas Type
Gas Quality
Gas Inlet Flow and Pressure
Gas Filtering
.
A complete Parts List is available at www.HobartWelders.com
SECTION 4 − SPECIFICATIONS
eff used
1
400 Volts DC/Electrode Negative
)
2 − No ingress of foreign objects  12.5 mm
3 − No harmful ingress spraying water
C − AC line circuits protected against ingress of
tool  2.5 mm dia x 100 mm long (0.1 in. x 4 in.)
S − Fan stationary during water test
1 PH
Volts AC RMS − (U
)
1
208 Volts
230 Volts
Volts AC RMS − (U
)
1
208 Volts
230 Volts
10.1 KW
Constant Current
20-40 A
Amps DC − (I
)
2
40 A
40 A
Duty Cycle %
50
50
5 to 104 F (−15 to 40 C)
(0.5 in.)
Up to 15 incline
Air or Nitrogen
Clean, moisture-free, oil-free
4.8 SCFM (85 L/min)
Particulates to 5 microns
60 Hz
— —
Amps RMS − (I
)
I
eff
1
1
33
23.3
30
21.2
Power Factor
KVA/KW
0.98
6.8/6.6
0.98
6.8/6.6
— —
— —
— —
— —
— —
— —
— —
— —
Volts AC
Volts DC − (U
)
2
RMS − (U
1
140 Volts DC
208 Volts
140 Volts DC
230 Volts
Volts AC
Amps DC − (I
)
2
RMS − (U
1
40 A
208 Volts
40 A
230 Volts
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
90 PSI (621 kPa)
120 PSI (827
Min
kPa) Max
— —
— —
OM-244 013 Page 11
)
)