Termination & Dip Switch Settings - Nuvico EasyTrack CK-1000 Instruction Manual

Controller keyboard ptz dome system
Table of Contents

Advertisement

2.2 Termination & Dip Switch Settings
The first and last devices in an installation (dome and controller keyboard) must have
the data line terminated by setting the DIP switch. Without proper termination, there
may be control signal errors. Total length of the cable for communication should not
exceed 0.74 Mile or 1.2 Kilometer.
SW1:Termination ON
SW1:Termination ON
SW1:Termination ON
S1:DOme1 port Termination On
SW1:Termination ON
S1:DOme1 port Termination On
SW1:Termination ON
S1:Dome1 port Termination On
S1:Dome1 port Termination On
S4:DVR port Termination On
Figure 6 – Termination
DVR Termination ON
DVR Termination ON
SW1:Termination ON
DVR Termination ON
DVR Termination ON
Repeater
CONTROLLER KEYBOARD
SW1:Termination ON
SW1:Termination ON
SW1:Termination ON
SW1:Termination ON
14

Hide quick links: