TROUBLESHOOTING
1. FREQUENT NUISANCE ALARMS OCCUR:
(1) Close kitchen / bathroom door when in use.
(2) Ensure that the alarm is sited at least 6m away from sources
of fumes.
(3) Contamination from insects, paint or paint fumes may have
occurred. Clean the alarm - see page 5.
(4) If the problem persists, resiting of the unit should be consid-
ered.
2. ALARM SOUNDS FOR NO APPARENT REASON:
(1) Identify the alarm source. On interconnected units, the red
light on the cover will flash rapidly only on the unit which is the
source of the alarm.
(2) Check for fumes, steam etc. from the kitchen or bathroom.
Paint and other fumes can cause nuisance alarms.
(3) Press the test/hush button to silence the Smoke/Heat Alarm
for 10 minutes.
(4) If alarm does not stop, switch off mains and remove unit (see
figure 1). (Only remove alarm with red light flashing, the oth-
ers are probably satisfactory).
3. LOW BATTERY & OTHER BEEPS:
(On EIi144/146 only)
If the battery is correctly connected and the unit has beeped for
over 20 minutes the battery is probably depleted. Obtain a new
battery, disconnect the mains, then remove the alarm and replace
the depleted battery.
(On Ei164/166 only)
Check the green mains power light is on. If not, check fuse, circuit
breakers and wiring connections. If the green light is off, the lithium
cells will deplete after some months without mains and will need to
be recharged. If the above fails to turn on the green light, a fault
may exist. Switch off mains and remove the unit (see figure 1).
(All Alarms)
(1) If the green mains light is on and replacing battery, recharging
lithium cells or cleaning unit has not stopped beeps, a fault
may exist. Disconnect the mains first and replace the unit
(see figure 1).
(2) The Ionisation units Ei140/161) give two beeps 10 minutes af-
ter the test//hush button is pressed.
(3) If the Optical units Ei 146/145/166) beeps without the red light
flashing at the same time, the chamber is defective. Clean the
chamber.
10
230V AC SMOKE & HEAT ALARMS
IONISATION
HEAT
RECHARGEABLE LITHIUM CELL BACK-UP
EI
EI
161
164
ALKALINE 9 VOLT BATTERY BACK-UP
EI141
EI144
NO BATTERY BACK-UP
EI
EI
140
143
If you are also the installer see separate
"Siting & Installation Instructions"
USER INSTRUCTIONS
KEEP FOR REFERENCE
READ THIS FIRST
IMPORTANT USER INFORMATION
REGULARLY CHECK THAT THE GREEN MAINS INDICATOR
4
LIGHT IS ON.
4
IF A NUISANCE ALARM OCCURS, PRESS THE TEST/HUSH
BUTTON TO SILENCE THE ALARM FOR 10 MINUTES.
IF THE UNIT BEEPS EVERY 40 SECONDS FOR OVER 20
4
MINUTES THE BATTERY IS PROBABLY DEPLETED AND
MUST BE REPLACED. SWITCH OFF THE MAINS AND RE-
MOVE THE UNIT AS SHOWN IN FIGURE 1A. REMOVE DE-
PLETED BATTERY AND REPLACE WITH ONE OF THE
SPECIFIED 9V ALKALINE BATTERIES. THE UNIT CANNOT
BE REPLACED ON THE MOUNTING PLATE UNLESS A BAT-
TERY IS INSTALLED. AFTER REPLACING THE BATTERY,
SLIDE ON TO THE MOUNTING PLATE THEN PRESS THE
TEST BUTTON AND ENSURE HORN SOUNDS LOUDLY BE-
FORE YOU TURN ON THE MAINS. IF IT IS SATISFACTORY
TURN ON THE MAINS AND CHECK THAT THE GREEN LIGHT
COMES ON.
PAGE 10 & 1
B13730
REV-1