ToTal assurance Package Cartridge Tested and Certified by NSF International against NSF/ANSI Standard 42 and 53 for the reduction of: TaP-42x series Standard No. 42: Aesthetic Effects Nominal Particulate Reduction Class I Standard No. 53: Health Effects Cyst Reduction Turbidity Reduction.
TAP-42X SerieS A.J. Antunes & Co. table Of cOntents Owner Information ...............2 Starting the Smart Controller ........... 12 General................2 Rinsing the Ultra Filter Cartridge........12 Warranty Information ............2 Rinsing the Carbon Element and Plumbing Service/Technical Assistance ..........3 (TAP-421 units only) ............
TAP-42X SerieS A.J. Antunes & Co. Owner InfOrmatIOn (continued) service/technical assistance Purchased From: If you experience any problems with the installation or opera- Date of Purchase: tion of your system, contact A.J. Antunes & Co. at 1-630-784- Model No.: 1000, or toll free in the United States at 1-800-253-2991.
Page 4
TAP-42X SerieS A.J. Antunes & Co. ImpOrtant safety InfOrmatIOn (continued) protect from becoming dry caUtIOn If the membrane dries out, irreversible damage to the Ultra this equipment is to be installed to comply with the Filter membrane may result. Protect the filter from becoming dry by keeping it wet and sealed at all times.
TAP-42X SerieS A.J. Antunes & Co. perfOrmance Data sHeet filter cartridge capacities Cartridge Tested and Certified by NSF Maximum Operating Pressure 100 psig (690 kPa) International against NSF/ANSI Maximum Operating Temp. 104°F (40°C) Standard 42 and 53 for the reduction of: Minimum Operating Temp.
Unpacking equipment setup General 1. Open the large box. It should contain: A. Plate mounted TAP-42x Series system with UFL When placing the system into service, pay attention to the cartridge installed (Figure 2). following guidelines: B. One 20-foot coil of flexible hose.
Page 9
TAP-42X SerieS A.J. Antunes & Co. InstallatIOn (continued) Inlet water plUmbInG Drain line If desired, a “T” or Cross Fitting with cap or plug can be from system secure installed between the Inlet Valve and the System Inlet. This fitting can be used for draining and sanitizing the system and 2”...
TAP-42X SerieS A.J. Antunes & Co. InstallatIOn (continued) caUtIOn The System is Due to its weight and size, the tap system mUst be designed to “hang” from mounted with the provided mounting bracket. read the Mounting Bracket the entIre section on Mounting the System befOre attempting to mount the tap system.
TAP-42X SerieS A.J. Antunes & Co. InstallatIOn (continued) Drain Hose connection The TAP System is shipped with a coil of braided tubing (20 feet) designed to direct the Drain Valve Solenoid water to the drain. Refer to Figure 7 and follow these steps: Drain Hose Connection 1.
TAP-42X SerieS A.J. Antunes & Co. InstallatIOn (continued) starting the smart controller rinsing the Ultra filter cartridge nOte: make sure that all ball valves are closed before The Ultra Filter Cartridge is pre-installed with the TAP System starting the system.
TAP-42X SerieS A.J. Antunes & Co. InstallatIOn (continued) 12. Wait until the display flashes r3 (approximately 15 rinsing the carbon element and plumbing minutes). The system beeps. (tap-421 units only) 13. manually open the Rinse Valve. The Carbon Element is used on TAP-421 units only. The Carbon Element must be rinsed before using the system the 14.
TAP-42X SerieS A.J. Antunes & Co. InstallatIOn (continued) sanitizing the system and lines 8. Reattach the plug on the sanitation fitting or inlet water line. nOte: If installed, remove the carbon element from the system befOre sanitizing. 9. Slowly turn on the water supply to the system.
TAP-42X SerieS A.J. Antunes & Co. OperatIOn Operation caUtIOn The TAP System is designed to operate with little to no user the system continues to filter water even after a power intervention. The system monitors and flushes itself automati- loss but it will nOt flush. therefore, running the system cally.
TAP-42X SerieS A.J. Antunes & Co. maIntenance replacing the Ultra filter cartridge nOte: make sure there is enough room next to the system to remove the cartridge. nOte: always install a new carbon element after replacing the Ufl cartridge. 6. Remove the Snap Ring from the Ultra Filter housing.
TAP-42X SerieS A.J. Antunes & Co. maIntenance (continued) 14. Install the Snap Ring by guiding the non-lugged end RED Pressure O-Ring into the groove first, pushing outward and working Relief Button around the ring until it snaps into place. Carbon...
TAP-42X SerieS A.J. Antunes & Co. maIntenance (continued) resetting the carbon element accumulated 15. Press the flUsH button to start the Pressurize System program. This allows the system to pressurize when the total Value Inlet valve is opened and make water available to the Carbon Element.
Page 19
TAP-42X SerieS A.J. Antunes & Co. maIntenance (continued) nOte: the system beeps every time a button is pressed. NOTE: When in normal operating mode, pressing both the ▲ and ▼ buttons displays the current software version. pOwer lOss tO system (system UnplUGGeD Or sUpply InterrUpteD) • Any active valve program is aborted...
Page 20
TAP-42X SerieS A.J. Antunes & Co. maIntenance (continued) serVIce menU access Press and hold in order, the VIew button and the ▲ button. 1. The red SYSTEM LED illuminates and the “--” appears in the display. 2. Release all buttons. The system displays “--”. 3. Use the ▲and ▼ buttons to select the desired function and press the flUsH button 4.
TAP-42X SerieS A.J. Antunes & Co. trOUblesHOOtInG problem possible cause corrective action The power cord is not plugged into the appro- Plug power cord into the appropriate outlet. priate outlet or control box. The unit is plugged into a switched electrical Plug the power cord into an unswitched outlet.
TAP-42X SerieS A.J. Antunes & Co. wIrInG DIaGram POWER CORD W/24V XFORMER CONTROL FLOW S1 S2 COM recOmmenDeD eqUIpment scHematIc Machine Drink SYSTEM System Service (Example) Coffee, Tea, Booster Espresso Pump Juice/ Non Carbonated Sanitation/ Pressure Cleaning Gauge Plug From...
TAP-42X SerieS A.J. Antunes & Co. replacement parts P/N 1010976 Rev. G 03/12...
Page 24
TAP-42X SerieS A.J. Antunes & Co. replacement parts (continued) P/N 1010976 Rev. G 03/12...
Page 25
TAP-42X SerieS A.J. Antunes & Co. replacement parts (continued) TAP 421 units ONLY NOTE: These items apply to TAP-421 units ONLY. This also includes the items noted on page 27 P/N 1010976 Rev. G 03/12...
Page 26
TAP-42X SerieS A.J. Antunes & Co. replacement parts (continued) P/N 1010976 Rev. G 03/12...
Page 27
TAP-42X SerieS A.J. Antunes & Co. replacement parts (continued) replacement parts can be purchased from an authorized dealer. contact a.J. antunes & co. at 1-630-754-1000 or toll free in the United states at 1-800-253-2991. Item part Description qty. Item part Description qty.
lImIteD warranty Equipment manufactured by A.J. Antunes & Co. has been constructed of the finest materials available and manu- factured to high quality standards. These units are warranted to be free from defects in materials and workman- ship for a period of one year from date of purchase under normal use and service, and when installed in accor- dance with manufacturer’s recommendations*. The ultra filtration membrane cartridge is warranted under the same terms and conditions on a prorated basis for 24 months from date of purchase.