MANUFACTURING
NUMBERS:
9700730
9700750
VZN T5 WATER
FILTRATION
System Tested and Certified by NSF
International and WQA against NSF/ANSI
VZN-421H-T5, VZN-441H-T5
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction as
verified and substantiated by test data.
System Tested and Certified by WQA
against NSF/ANSI Standard 372
for lead-free compliance
P/N 1011066 Rev. G 12/13
Owner
s Manual
'

Advertisement

Table of Contents
loading

Summary of Contents for Vizion VZN-421H-T5

  • Page 1 VZN T5 WATER FILTRATION System Tested and Certified by NSF International and WQA against NSF/ANSI VZN-421H-T5, VZN-441H-T5 Standard 42 and 53 for the reduction of: Standard No. 42: Aesthetic Effects Nominal Particulate Reduction Class I Standard No. 53: Health Effects Cyst Reduction &...
  • Page 2: Table Of Contents

    VZN T5 SERIES TABLE OF CONTENTS Owner Information ...............2 System Inlet Connection ..........12 General................2 Filtered Water Permeate Outlet Connection ....12 Warranty Information ............2 Inlet Water Plumbing ............12 Service/Technical Assistance ..........3 Installing a Bypass ............13 Important Safety Information ..........4 Starting the Controller ............
  • Page 3: Service/Technical Assistance

    VZN T5 SERIES OWNER INFORMATION (continued) Service/Technical Assistance Suggested replacement period for the Ultra Filter Cartridge is If you experience any problems with the installation or opera- approximately 3 years. tion of your system, contact A.J. Antunes & Co. at 1-630-784- 1000, or toll free in the United States at 1-800-253-2991.
  • Page 4: Important Safety Information

    VZN T5 SERIES IMPORTANT SAFETY INFORMATION In addition to the warnings and cautions in this manual, use The following warnings and cautions appear throughout this the following guidelines to safely operate the system: manual and should be carefully observed. • Read all instructions before using equipment. •...
  • Page 5 VZN T5 SERIES IMPORTANT SAFETY INFORMATION (continued) Protect from becoming dry CAUTION If the membrane dries out, irreversible damage to the Ultra This equipment is to be installed to comply with the Filter membrane may result. Protect the filter from becoming basic plumbing code of the Building Officials and Code dry by keeping it wet and sealed at all times.
  • Page 6: Specifications

    VZN T5 SERIES SPECIFICATIONS Electrical Ratings Dimensions Model & Volts Watts Amps Hertz Mfg. No. VZN-421H-T5 VZN-441H-T5 VZN-421H-T5 100–240 50/60 9700730 VZN-441H-T5 100–240 50/60 9700750 NOTE: Includes plug adaptors for US, Europe, Australia, and UK. Replacement Cartridges Replacement Part Number...
  • Page 7: Performance Data Sheet

    100 kD Particles 0.5 to < particles /mL NSF/WQA Certified Rated Service 1µm Flow: VZN-421H-T5 7.9 gpm (30 l/m) based on the use of microspheres or Cryptosporium parvum oocysts VZN-441H-T5 13 gpm (49 l/m) System Tested and Certified by NSF...
  • Page 8: Operation

    VZN T5 SERIES OPERATION Overview The VZN system operates in two modes: System Inlet Flush Ball Valve • Normal Operation Mode Solenoid (Manual) Valve • Flush Mode (Automatic) During Normal Operation Mode, water enters the Inlet and flows through the Ultra Filter before exiting the Permeate Outlet Outlet as usable product water.
  • Page 9: Installation

    VZN T5 SERIES INSTALLATION Unpacking Equipment Setup GENERAL 1. Open the large box. It should contain: A. Plate-mounted VZN system with Ultra Filter When placing the system into service, pay attention to the Cartridge installed following guidelines: B. Padded envelope containing: •...
  • Page 10: Mounting The System

    VZN T5 SERIES INSTALLATION (continued) CAUTION The system is designed to hang from Due to its weight and size, the VZN system MUST be the Mounting Bracket. Back Plate mounted with the provided Mounting Bracket. Read (holes along bottom the Mounting the System section before attempting to for additional mount the VZN system.
  • Page 11: Drain Valve Connection

    VZN T5 SERIES INSTALLATION (continued) Drain Valve Connection The drain is for flushing particle buildup out of the system during self cleaning. Example Drain Valve Connection 1. Cut a length of tubing (not supplied) so it reaches the drain from the Drain Valve. Secure Hose 2.
  • Page 12: Rinse Valve Connection

    VZN T5 SERIES INSTALLATION (continued) Rinse Valve Connection Rinse Valve Connection 1. Obtain a length of 3/4” garden hose long enough to reach from the Rinse Valve to the drain. 3/4” 2. Install a gasket in the end of the hose (non-drain end). Garden Hose 3.
  • Page 13: Installing A Bypass

    VZN T5 SERIES INSTALLATION (continued) Rinsing the Ultra Filter Cartridge Water The Ultra Filter Cartridge comes pre-installed in the VZN Flow system. The Ultra Filter Cartridge must be rinsed before the system is used to remove any air and protective solution. NOTE: Ultra Filter Cartridge must be rinsed to drain before use.
  • Page 14: Sanitizing The System And Lines

    VZN T5 SERIES INSTALLATION (continued) Sanitizing the System and Lines Rinsing the Carbon Element and TAC Cartridge The plumbing must be sanitized to eliminate possible contam- The Carbon Element and TAC Cartridge MUST be rinsed ination that may have occurred during the installation process. before using the system the first time and immediately after the Carbon Element or TAC Cartridge have been replaced.
  • Page 15: Maintenance

    VZN T5 SERIES MAINTENANCE Replacing the Ultra Filter Cartridge NOTE: Always install new Carbon Element and new Snap Ring TAC Cartridge Element after replacing the Ultra Filter Cartridge. 1. Turn off water to the system by closing the Inlet Ball End Cap Valve and Outlet Ball Valve.
  • Page 16: Rinsing And Replacing The Carbon Element

    VZN T5 SERIES MAINTENANCE (continued) Rinsing and Replacing the Carbon Element RED Pressure O-Ring NOTE: Remove the TAC Cartridge Element, if present, Relief Button and re-attach the TAC Housing before proceeding. Carbon Element 1. Turn off the water to the system by closing the Inlet Ball Head Valve and Outlet Ball Valve.
  • Page 17: Rinsing And Replacing The Tac Cartridge

    VZN T5 SERIES MAINTENANCE (continued) NOTE: Do not perform this procedure with a new Car- bon Element installed. 1. Turn off water to the system by closing the Inlet Ball Valve and then close the Outlet Ball Valve. 2. Press the FLUSH button to initiate the flush cycle. Repeat several times to ensure the permeate tank is empty.
  • Page 18: Changing The Interval Setting

    VZN T5 SERIES MAINTENANCE (continued) Changing the Interval Setting Semi-Annual Tasks Check Permeate Tank Air Pre-Charge CAUTION Changing the flush interval can cause the Ultra Filter to It is recommended the permeate tank air charge be plug prematurely and may reduce the life of the filter. checked every six months.
  • Page 19: Troubleshooting

    VZN T5 SERIES TROUBLESHOOTING Problem Possible Cause Corrective Action The power cord is not plugged into the Plug power cord into the appropriate outlet. appropriate outlet or control box. The unit is plugged into a switched Plug the power cord into an unswitched outlet. Unit does not have power.
  • Page 20: Replacement Parts

    VZN T5 SERIES REPLACEMENT PARTS VZN-421H-T5 Systems P/N 1011066 Rev. G 12/13...
  • Page 21 VZN T5 SERIES REPLACEMENT PARTS (continued) VZN-441H-T5 Systems P/N 1011066 Rev. G 12/13...
  • Page 22 VZN T5 SERIES REPLACEMENT PARTS (continued) Replacement Parts can be purchased from an authorized dealer. Contact A.J. Antunes & Co. at 1-630-754-1000 or toll free in the United States at 1-800-253-2991. VZN-421H-T5 Systems Item Part Description Qty. Item Part Description Qty.
  • Page 23: Notes

    VZN T5 SERIES NOTES P/N 1011066 Rev. G 12/13...
  • Page 24: Limited Warranty

    LIMITED WARRANTY Equipment manufactured by A.J. Antunes & Co. has been constructed of the finest materials available and manu- factured to high quality standards. These units are warranted to be free from defects in materials and workman- ship for a period of one year from date of purchase under normal use and service, and when installed in accor- dance with manufacturer’s recommendations*.