Mitsubishi Electric Mr.Slim PEAD-A24 Installation Manual page 7

Hide thumbs Also See for Mr.Slim PEAD-A24:
Table of Contents

Advertisement

8
[Fig. 8-3]
A Indoor terminal block
2
1 2
5
1
6
3
D Outdoor terminal block
[Fig. 8-4]
A
30
[1-3/16]
C
[Fig. 8-5]
D
A
C
E
F
I
H
A For installation in the switch box:
B For direct installation on the wall select one of the following:
• Prepare a hole through the wall to pass the remote controller cord (in order to run the remote controller cord from
the back), then seal the hole with putty.
• Run the remote controller cord through the cut-out upper case, then seal the cut-out notch with putty similarly as
above.
[Fig. 8-6]
A
B Earth wire (green/yellow)
4
C Indoor/outdoor unit
connecting wire
2
3-core 1.5 mm
[AWG 16] or more
B
(Unit: mm [in])
30
[1-3/16]
46 [1-13/16]
A Remote controller profile
B Required clearances surrounding the remote controller
C Installation pitch
B
B-1.
H
G
I
AB
TB6
B
8.2
A Indoor terminal block
B Earth wire (green/yellow)
C Indoor/outdoor unit connecting wire 3-
core 1.5 mm
2
[AWG 16] or more
D Outdoor terminal block
1 Connecting cable
Cable 3-core 1.5 mm
2
[AWG 16], in con-
formity with Design 245 IEC 57.
2 Indoor terminal block
3 Outdoor terminal block
8.3
B-2.
H
I
A To the terminal block on the indoor unit
B TB6 (No polarity)
4 Always install an earth wire (1-core 1.5 mm
[AWG 16]) longer than other cables
5 Remote controller cable
Wire No × size (mm
2
) : Cable 2C × 0.3
This wire accessory of remote controller
(wire length : 10 m [32 ft], non-polar.
Max. 500 m [1640 ft])
6 Wired remote controller
J
C Wall
D Conduit
E Lock nut
F Bushing
G Switch box
H Remote controller cord
I Seal with putty
J Wood screw
2
7