PROBLEM
Excessive tank
pressure - safety
valve pops off.
Air leaks at
fittings.
Air leak from
safety valve.
Knocking Noise.
Pressure reading
on the regulated
pressure gauge
drops when an
accessory is
used.

TROUBLESHOOTING

Risk of Unsafe Operation. Performing repairs may expose
voltage sources, moving parts or compressed air sources.
CAUSE
Pressure switch does not
shut off motor when
compressor reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Tube fittings are not tight
enough.
Possible defect in safety
valve.
Possible defect in safety
valve.
It is normal for "some"
pressure drop to occur.
Move Off/Auto-On switch to
the "Off" position, if the unit
does not shut off contact a
Trained Service Technician.
Contact a Trained Service
Technician.
Tighten fittings where air can
be heard escaping. Check
any exposed fittings with
soapy water solution. Do Not
Overtighten.
Apply sealant tape to threads
of exposed fittings.
Operate safety valve
manually by pulling on ring.
If valve still leaks, Contact a
Trained Service Technician.
Operate safety valve
manually by pulling on ring.
If valve still leaks, Contact a
Trained Service Technician.
If there is an excessive
amount of pressure drop
when the accessory is used,
adjust the regulator following
the instructions in the
"Description of Operation"
paragraph in the "Operation
Section.
NOTE: Adjust the regulated
pressure under flow
conditions (while accessory
is being used).