Know Your Air Compressor
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the
location of various controls and adjustments. Save this manual for future reference.
Off/Auto-On Switch
Power
Cord
Safety
Valve
Regulator
Tapered
Inflator
Rubber
Tip
Nozzle
Description of Operation
Become familiar with these controls
before operating the unit.
Off/Auto-On Switch: Turn this switch
to "Auto-On" to provide automatic
power to the pressure switch and
"Off" to shut off the power.
Pressure Switch (not shown): The
pressure switch automatically starts
the motor when the air tank pressure
drops below the factory set "cut-in"
pressure. It stops the motor when the
air tank pressure reaches the factory
set "cut-out" pressure.
D29728
D29728

OPERATION

Female
Inflating needle
Tire
Chuck
12- ENG
Blow Gun Adapter
Safety Valve: If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
safety valve will protect against high
pressure by "popping out" at its
factory set pressure (slightly higher
than the pressure switch "cut-out"
setting).
Outlet Pressure Gauge: The outlet
pressure gauge indicates the air
pressure available at the outlet side
of the regulator. This pressure is
controlled by the regulator and is
always less than or equal to the tank
pressure.
Accessory
Storage
Safety Nozzle
Blow
Gun
Outlet
Pressure
Gauge
Air
Hose
Drain Valve,
not shown