Trigger - Photon Focus MV1-D1312C CameraLink Series User Manual

Cmos area scan colour camera
Table of Contents

Advertisement

7.1.3 Trigger

This tab contains trigger and strobe settings.
Figure 7.4: MV1-D1312C-160 trigger panel
Trigger
Trigger Source:
Free running: The camera continuously delivers images with a certain configurable frame rate.
Interface Trigger: The Trigger signal is applied to the camera by the CameraLink frame grabber
or the USB interface respectively.
I/O Trigger: The trigger signal is applied directly to the camera on the power supply connector.
Exposure time defined by:
Camera: The exposure time is defined by the property ExposureTime.
Trigger Pulse Width: The exposure time is defined by the pulse width of the trigger signal
(level-controlled exposure).
This property disables LinLog, Burst trigger and simultaneous readout mode.
Exposure time defined by "Trigger Pulse Width" is also known as Level controlled
trigger.
Further trigger settings:
7.1 MV1-D1312C-160
73

Advertisement

Table of Contents
loading