Service Data Sheet - Electrolux European Wine Tower Service Manual

Table of Contents

Advertisement

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS
AT MID-POINT CONTROL SETTING
type a with run/start
65°f (18°c) ambient
capacitor
Operating Time
N/A
Wine Cooler Temperature
45º F to 65º F
30 to 45 psig
Low Side Pressure (cut-in)
208 to 310 kPa
-2 to 4 psig
Low Side Pressure (cut-out)
-14 to 28 kPa
High Side Pressure
90 to 120 psig
(last 1/3 cycle)
621 to 827 kPa
Wattage (last 1/3 cycle)
85 to 125
Amps (running)
.75 to 1.2
Base Voltage
115 vac (127 vac max)
cONdeNser faN mOtOr
Watts
rpm
2.3
1100 CW Opposite Shaft
WiNe cOOLer evapOratOr faN mOtOr (Quantity 2)
2.76 each
1800
impOrtaNt: pLease returN this sheet tO its OriGiNaL LOcatiON.

service data sheet

90°f (32°c) ambient
WiNe cOOLer - r134a
14 to 37%
45º F to 65º F
30 to 45 psig
208 to 310 kPa
cautiON
-2 to 4 psig
-14 to 28 kPa
all electrical parts and wiring must be shielded from torch
130 to 175 psig
flame. dO NOt allow torch to touch insulation; it will char
896 to 1207 kPa
at 200°f and flash ignite (burn) at 500°f. excessive heat will
85 to 125
distort the plastic liner.
.75 to 1.2
NOte
amps
Your Electrolux wine keeper has been designed for either
0.15 Running
free-standing or built-in installation. When built-in, your wine
keeper does not require additional air space for top, sides or
rear. In either case, the front grille must NOt be obstructed.
.23 each
To ease unit installation and removal, it is recommended that
the cabinet rough opening dimensions be increased by at
least ¼ inch over the dimensions given for your unit.
All units require zero clearance when installed flush with a
cabinet or wall. Electrolux stainless steel models require a
minimum handle clearance when installed against a wall or
cabinet that extends beyond the front edge of the unit.
impOrtaNt safety NOte
The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing this appliance.
impOrtaNt
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.
241995900
3"
Width
Height
23
1
/
inch
75-76 inches
2
29.875" (75.88 cm)
27.50" (69.85 cm)
23.50" (59.69 cm)
24.875" (63.18 cm)
Side
Front
75-76"
View
View
(191-193 cm)
2.75"
(6.98 cm)
(8.25 cm)
unit dimensions
Depth
24
7
/
inch
8
23.50" (59.69 cm)
Top
View
3.00"
(7.62 cm)
49"
(124.46 cm)
3.25"

Advertisement

Table of Contents
loading

Table of Contents