Invacare Bora Service Manual page 94

Invacare bora/spectra xtr wheelchair service manual
Hide thumbs Also See for Bora:
Table of Contents

Advertisement

SERVICE MANUAL
· Remove the SL fuse (2) on the bottom fixing
bolt (1) with the screwdriver.
· Pull the fixing bolt (1) out.
· Remove the SL fuse (2) on the top fixing bolt
(1) with the screwdriver.
· Pull the fixing bolt (1) out.
· Pull the adjustment spindle with adjusting
motor out.
· Insert a new adjustment spindle with adjusting
motor.
· Reinsert the fixing bolts and SL fuses. Fix the
SL fuses securely to the fixing bolt with the
hammer.
· Reinsert the adjusting motor plug into the
electronics module.
· Secure the adjusting motor cable to the frame
with cable ties. The cable must be routed so
that it does not rub or get trapped.
· To complete, check all seat tilting functions.
94
®
Invacare
- Bora/Spectra XTR

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spectra xtr

Table of Contents