Download Print this page

Installation - Gabarron GTV Installation, Setup, Maintenance

Gtv ceramic vertical range from 75 to 200 l gth horizontal range of 100 and 150 l gte small capacity range of 30 and 50 l

Advertisement

Capacity
Litres
100
150
**DISTANCE BETWEEN SUPPORTS
Capacity
Litres
30
50
The water heater must be installed as close as possible to the point of use and protected
from possible freezes. When choosing the place, you must take into account the fact that
the water entry and exit tubes must be easily accessible and avoid the use of bends as far
as is possible, so it can be de-assembled and so any of its components can be replaced
without a problem.
NOTE: Before setting it up, it is essential to ensure the water heater is adapted to the
voltage available in the network (see Electrical Connection section).
HORIZONTAL RANGE – GTH
Power
Maintenance
W
Consumption at
65° (kWh/24h)
1600
1,16
2200
1,54
SMALL CAPACITY RANGE – GTE
Power
Maintenance
W
Consumption
at 65° (kW/24h)
2000
0,73
2000
0,9

INSTALLATION

A
B**
C
mm
mm
mm
860
600
580
1182
800
580
B
A*
D
C
mm
mm
mm
mm
623
338
463
345
918
338
750
345
Net
weight
D
(kg)
mm
600
34
600
45
Net
E
Weight
mm
(kg)
81
13
81
18

Advertisement

loading

This manual is also suitable for:

GthGte