Operating Specifications; Heater Performance Specifications; Monitor 441; Section 3 : Operation - Monitor 422 Service Manual

Monitor heating systems
Table of Contents

Advertisement

MONITOR
HEATING SYSTEMS
Section 3 : Operation
3-1
INTRODUCTION
Monitor is an easy-t~operate vented kerosene
heater. Routine operation features high BTU output.
automatic adjustment of room temperature, low fuel
and power consumption, and choice of automatic or
manual heater operation.
This section provides
all
information necessary to
operate
the
Monitor Heating System. All operation
procedures specified should be performed in the
order in which
they
are described.
3-2
OPERATING
SPECIFICATIONS
The following specifications apply to the operation
of the Monitor
441
and the Monitor 422.
Monitor
441
-
Rated Efficiency (as applied
to
kerosene
heaters):
9 3 % '
-
Rated
Efficiency (as applied to central heating
systems): 87%
-
Power Consumption : as follows
-
Circulation Fan
O u t p u t
:
388 cubic feet:min.
-
Fuel
source : Remote, separate tank
-
Potential heating area : 900-3200 sq.
feet
'The
energy from the combustion process
IS
released in the form of heat
and
vaporized water.
Normally. heating systems discharge water from
combustion to the atmosphere without condensing
it. This
93%
efficiency rating means
that.
assuming
the
water cannot be condensed,
93% of
the heat
produced by the combustion process is recovered.
Assuming the water can
be
condensed, the effi-
ciency is 87%.
NOTE:
Actual effective heatirig area depends upon
numerous factors such as type and severii
of climate, type of dwelling construction,
condition of dwelling, and thickness
and
effectiveness of dwelling insulation.
Table
3 1 lists
Monitor 641 performance specifica-
tions at various user-selected heat output settings.
HlGH
MEDlUMHlGH
MWUMLOW
LOW
IGNITION
BUR4
BURN
BURN
BUFIN
340watts 65watls m a t t s
58-
58wam
Table 3-1
HEATER PERFORNlANCE
SPEUFlCATlONS
I
Rating
I
1 6 , 2 0 0
I
Z I , M X )
1
3 3 . 9 0 0
I
43.cm
I
Specification
I
I
I
I
Heater Output/hr.
I
15.000
I
19.W
I
3 . 5 0 0
1
40.0OO
Ssthng
Fuel Consum~tion (~al/hr)
&hrs/day burntime (5-gal.
tank)
High
Bhrs/day burntime (55gal.tank)
Continuous-use bumtime (55-gal.tank)
Bhrs/day bumtirne (275-gal-tank)
Continuous-use bumtime
(275-~al.tank)
Medium
High
Low
,
Medium
Low
1
0.39
2.WaYs
,025
25daP
0 . 1 2
52days
2Y.Mays
7
2days
107.8days
35.9days
57.3days
l 9 . l d a y s
2BS.5days
955days
0 . 1 6
3.9days
43days
(
27.5days
,
14.3days
214.fflays
71.6days
Q2days
137.5days
45.8days

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

22214144140

Table of Contents