MONITOR HEATING SYSTEMS
Section 6: Troubleshooting
Monitor
422/441
Resistance
values
COMPONENT
APPROX.
OHMS
M-422
M a 1
Igniter (connector B/B)
16.8
12.7
Power Transformer
-
Primary (AC
120V)
125
125
Power Transformer
-
Secondary (AC
12V)
1.6
1.6
Power Transformer
-
Secondary (AC
120V)
M7
647
Damper Solenoid (connector 1/1)
4.600
4.600
Resistor (connector
G/G)
63
W
Circulation Fan (M-422:RD 8 BK, M41:WH 8 BK)
235
115
Circulation Fan (M-422:BK
B
Y L M-441:BK
&
EL)
247.5
258.5
Combustion Blower (M-422:BK 8 BK, M-M1:WH
B
GR)
22
78
Combustion Blower(M41:GR
B
OR)
-
92
Thermistor (connector O/Q, at
7 7
F )
10,000
10.000
Fuse 2A (read
with
fuse out)
0.1
0.1
Fuse 10A (read
with
fuse out)
0 . 0 1
0.01
Solenoid
Pump
(coil)
565
565
MSCONNECT
HEATER
FROM
POWER
SOURCE
BEFORE MAKING ANY RESSTANCE VESTS.