Kenmore 148.03447410 Use & Care Manual page 32

Liquid propane gas grill

Advertisement

Available languages

Available languages

Problem
Possible Cause
Corrective Action
Burner blows out
Low heat with the
knob in "HI"
position
Low heat,
Sudden drop in gas
flow or low flame
1. LP tank is empty.
2. Burner is not aligned with the
control valve.
3. Gas supply is not sufficient.
1. Ports are blocked.
2. LP tank has run out.
The propane regulator
assembly incorporates an excess
flow device designed to supply the
grill with sufficient gas flow. Rapid
changes in pressure can trigger the
excess flow device, providing a low
flame and low temperature.
1. Out of gas.
2. Excess flow valve tripped.
3. Vapor lock at coupling nut/LP
cylinder connection.
1. Refill the LP Tank.
2. Install the burner correctly.
3. Check the gas supply hose and make
sure there are no leaks and no knots.
1. Clear ports of any obstructions.
2. Refill the LP tank.
Please follow these instructions:
1. Make sure all burners are "OFF".
2. Open the tank valve and wait 5
minutes.
3. Light the burner one at a time
following the lighting instructions
listed on the door liner
,
2.
Check for gas in LP cylinder.
Turn off knobs, wait 30 seconds and light grill.
If flames are still low, turn off knobs and LP
cylinder valve. Disconnect regulator.
Reconnect regulator and leak test. Turn on
LP cylinder valve, wait 30 seconds and then
light grill.
3. Turn off knobs and LP cylinder valve.
Disconnect coupling nut from cylinder.
Reconnect and retry.