Solahart Streamline Gas Owner's Manual page 14

Gas boosted solar water heater
Hide thumbs Also See for Streamline Gas:
Table of Contents

Advertisement

RECOMMENDED TIMER ON/OFF SETTING
It is recommended the timer be set to enable boosting between 4:00 PM (16:00 Hours) and
6:30 PM (18:30 Hours).
Note: The timer uses a 24 hour clock.
This two and a half hour boosting period is sufficient to allow the gas burner to heat up the entire
contents of the solar storage tank through a 45°C temperature rise. This may be necessary during
periods of very low solar energy gain through the solar collectors, such as during constant rain or
extremely cloudy weather.
It may be necessary and is recommended to reset the timer during daylight saving time (in the states
where applicable), to enable boosting between 5:00 PM (17:00 Hours) and 7:30 PM (19:30 Hours), to
maximise the solar energy gain during this period.
RESET THE TIMER
It is recommended the timer be reset before commencing the initial programming. This will delete any
set programs.
Press the "R" (reset) button gently to reset the timer.
Use a non-metallic object like a wooden or plastic
toothpick.
Warning: Do not use a sharp metal object as this
may pierce the protective membrane and an electric
shock may result.
Note: When the "R" (reset) button is pressed, the entire screen is illuminated and all programs,
including the current time, are deleted from the timer's memory.
TO SET THE TIME
Press and hold the "TIME" button.
Press the "DAY" button to select the current day.
Press the "HR" button to select the current hour
(Note: 24 hour clock).
Press the "MIN" button to select the current minute.
Release the 'TIME' button.
The current time is now set.
TIMER OPERATION
14
MO TU WE TH FR SA SU
TIMER
88:88
ON
OFF
13:30
OFF
TIME PROG DAY
RANDOM
R
Example: Setting the current time as
Sunday at half past one in the afternoon
i.e. 1:30 PM.
A
P
SU
HR
MIN
MAN

Hide quick links:

Advertisement

Table of Contents
loading