Removing  Gear  Box   A Ssembly; Inserting  Circuit  Board; Connecting  The  Circuit  Board - Pentair Fleck7000SXT Service Manual

Water softener
Hide thumbs Also See for Fleck7000SXT:
Table of Contents

Advertisement

Figure  3  
1.   Unplug  the  power  source.
2.   With  3/8"  nut  driver,  turn  the  cycle  cam  counter-­clockwise  to  
the  position  shown  in  illustration  above.
3.   Slightly  pull  the  two  tabs  outward  and  push  the  gearbox  
slightly  upward  to  remove.
4.   When  returning  valve  to  service  after  powerhead  
disassembly,  manually  step  valve  through  regeneration  
using  the  extra  cycle  button  until  valve  is  in  service.
1.   To  insert  the  circuit  board,  align  the  notches  on  the  left  
Apply  pressure  to  the  left  while  rotating  the  board  back.
Figure  4  
2.   When  all  the  way  down,  snap  the  circuit  board  into  place  
under  the  notches  on  the  right.
40988  REV   A
After  the  circuit  board  is  installed:
1.   Connect  the  motor  wires  (A)  to  the  motor  connector  (A1)  on  
board.
2.   Connect  the  transformer  cable  (B)  to  the  transformer  
connector  (B1)  on  board.
3.   Connect  the  meter  cable  (C)  to  the  meter  cable  connector  
(C1)  on  board.
4.   Connect  the  meter  cable  sensor  end  to  the  opening  on  the  
valve  body.
5.   Thread  meter  cable  (D1)  and  power  wire  (D2)  along  path  
shown  in  illustration.
A
41033  REV  B
Figure  5  
1
B1
A1
C1
D2
D1
Figure  6  
41033  REV  B
2
B
3
C
4
41033  REV  B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fleck 7000sxt

Table of Contents