Draught Limiter - Baxi Solo Innova Instructions Manual

Wood-fired central heating boiler
Table of Contents

Advertisement

1.4.2
Fan
1.4.3
Thermal outflow protection
1.4.4
Flue gas turbulators
1.4.5
Load valve
1.4.6

Draught limiter

INSTRUCTIONS
The total air flow is set at the factory.
The standard version of the Solo Innova does not have a cooling spiral. This spiral can
be mounted to the left or the right.
The flue gas turbulators are in the heat exchanger pipe and reduce the flue gas
temperature.
The thermostatic load valve enables the boiler to remain at a high temperature. As the
valve only opens at 65°C, the boiler thermostat must be set higher (i.e. fixed max. 90-
95°C). The load valve is supplied as a separate valve or as a complete pipe complex
ready for installation in the boiler. (See functional description of the load valve in
Section 4.3).
The guarantee is not valid unless a thermostatic load valve is installed.
If the chimney draught is excessive, a draught limiter can be built into the chimney (see
Section 3.3.3).
Solo Innova
Page 11