ActronAir LM7-D Operating Instructions Manual

ActronAir LM7-D Operating Instructions Manual

Air conditioner ultima zone control
Hide thumbs Also See for LM7-D:

Advertisement

AIR CONDITIONER
ULTIMA ZONE CONTROL

Operating Instructions

Master Controller

LM7-D
Ultima Zone Controller
LM-ZC
Please Read This Manual
Congratulations on your purchase of an
ActronAir air conditioning system. This unit
has been designed and manufactured with
the highest quality standard in mind.
Please read this manual carefully and keep it
for future reference.
Copyright © 2013
All rights reserve. No part or contents of this book maybe reproduced or transmitted in any
form or by any means without the written permission of Actron Engineering Pty. Ltd.
®
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LM7-D and is the answer not in the manual?

Questions and answers

Summary of Contents for ActronAir LM7-D

  • Page 1: Operating Instructions

    Ultima Zone Controller LM-ZC Please Read This Manual Congratulations on your purchase of an ActronAir air conditioning system. This unit has been designed and manufactured with the highest quality standard in mind. Please read this manual carefully and keep it for future reference.
  • Page 2: Table Of Contents

    Microprocessor Control that automatically controls and regulates conditioned air in each zone to provide year-round climate control and comfort. INSIDE THIS MANUAL You will fi nd instructions for Zone Controller used with ActronAir ESP Ultima system. Functions of the Master Controller, LM7-D and LM24W in conjunction with ESP Ultima operation, are also explained.
  • Page 3: Zone Controller Functions

    ZONE CONTROLLER FUNCTIONS ZONE COOL HEAT AUTO Z O N E C O N T R O L ROOM TEMP TEMP MODE ON/OFF Zone Controller Mode ON/OFF Button Zone Indicator Turn the zone ON or Off. ESP Auto Indicator Room Temperature Button Illuminates when zone controller is View actual room temperature.
  • Page 4: Turning Zone Controller On

    Master Controller set point temperature. This is a factory set limit, which is recommended in order to maintain system accuracy and maximize effi ciency. Should this require changing, contact ActronAir Technical support on freecall number : 1800 119 229 • Master Controller shown above is LM7-D, same procedure applies with LM24W model.
  • Page 5: Esp Auto Mode

    ESP AUTO MODE Indications of COOL or HEAT will show zone conditioning. (When zone damper is providing warm or cold air to your zone). COOL AUTO AUTO HEAT / COOL HEAT / COOL ZONE COOL HEAT PROGRAM TIMER AUTO SET TEMP SET TEMP SELECT REPEAT /...
  • Page 6: Zone Damper Blade Indicator

    ZONE DAMPER BLADE INDICATOR DISPLAY STATUS FULLY OPEN DAMPER BLADE Allows full airfl ow through in order to meet your required conditions. PARTIALLY CLOSED DAMPER BLADE Regulating airfl ow and temperature to meet set conditions. PARTIALLY OPEN DAMPER BLADE Regulating airfl ow and temperature to meet set conditions.
  • Page 7: Fan Only Mode

    FAN ONLY MODE COOL AUTO AUTO HEAT / COOL HEAT / COOL PROGRAM TIMER SET TEMP SET TEMP SELECT REPEAT / REPEAT / EXIT FAMILY KITCHEN RUMPUS DINING MASTER BED MASTER BED BEDROOM 1 BEDROOM 1 BEDROOM 2 BEDROOM 2 BEDROOM 3 BEDROOM 3 Master Wall Controller...
  • Page 8 FAN ONLY MODE ZONE COOL HEAT AUTO Z O N E C O N T R O L ROOM TEMP TEMP MODE ON/OFF Zone Controller FAN MODE will be displayed on zone control display when the Master Wall Controller is set to circulation operation. During this period, zone damper will be in fully open position for maximum air circulation.
  • Page 9: Zone Temperature Display

    ZONE TEMPERATURE DISPLAY TO CHECK TEMPERATURE AT MASTER WALL CONTROLLER COOL AUTO AUTO HEAT / COOL HEAT / COOL PROGRAM TIMER SET TEMP SET TEMP SELECT EXIT REPEAT / REPEAT / FAMILY KITCHEN RUMPUS DINING MASTER BED MASTER BED BEDROOM 1 BEDROOM 1 BEDROOM 2 BEDROOM 2...
  • Page 10 ZONE TEMPERATURE DISPLAY TO CHECK TEMPERATURE AT ZONE CONTROLLER ZONE COOL HEAT AUTO Z O N E C O N T R O L ROOM TEMP TEMP MODE ON/OFF Zone Controller Press the button. ROOM TEMP Actual room/zone temperature will be displayed for several seconds then display will return to setpoint temperature.
  • Page 11: Zone Open Mode

    ZONE OPEN MODE COOL AUTO AUTO HEAT / COOL HEAT / COOL PROGRAM TIMER ZONE COOL HEAT SET TEMP SET TEMP SELECT AUTO REPEAT / REPEAT / EXIT Z O N E C O N T R O L ROOM FAMILY KITCHEN RUMPUS...
  • Page 12: Trouble Shooting

    TROUBLE SHOOTING Condition Causes or Check Points The system does • Check that 5 minutes has passed from the time you turned not start. the system on, as the system has in-built safety timers. • Check thermostat settings are correct. •...
  • Page 13: Frequently Asked Questions

    Master Controller. A. 2 is the default setting for master temperature offset. ActronAir recommend this 2 offset to optimise temperature control and maximize energy effi ciency. Moving this setting +/- 2 will result in temperature inaccuracy. Contact ActronAir technical support: Tel.
  • Page 14 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 15 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 16 1800 119 229 actronair.com.au Actron Engineering Pty Ltd Printed in Australia Part No. 0500-122 ABN 34 002 767 240 Version: 03 130612 HEAD OFFICE SYDNEY AUSTRALIA...

This manual is also suitable for:

Lm-zc

Table of Contents