Control interface
Hide thumbs Also See for CL01-2W:

Advertisement

WALL CONTROL
Installation Instructions
Control Interface
Model Number
CL01-2W (White)
CL01-2G (Grey)
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.
AVAILABLE AS AN OPTIONAL ACCESSORY
FOR TRI-CAPACITY MODELS ONLY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL01-2W and is the answer not in the manual?

Questions and answers

Summary of Contents for ActronAir CL01-2W

  • Page 1 WALL CONTROL Installation Instructions Control Interface AVAILABLE AS AN OPTIONAL ACCESSORY FOR TRI-CAPACITY MODELS ONLY Model Number CL01-2W (White) CL01-2G (Grey) IMPORTANT NOTE: Please read this manual carefully before installing or operating your air conditioning unit.
  • Page 2: Table Of Contents

    CL01-2 Control Interface Installation Guide Table of Contents 01. Safety Precautions ........................3 02. Specifications ..........................3 03. Installation ...........................3 04. Wiring Diagram ..........................5 05. Assigning Sensor ......................... 6 Installation Guide - CL01-2 Control Interface Insert Document: 9590-3026 Ver. 2 220907...
  • Page 3: 01. Safety Precautions

    • Dimensions - mm: 130 x 130 x 14.5 (W x H x D) NOTE Do not use ActronAir 4 Core Data Cable Part Numbers: 4070-003 / AMDC4 or Non-Twisted Pair multi core cable. 03. Installation 1. Remove front cover, as shown in the diagram below 2.
  • Page 4 CL01-2 Control Interface Installation Guide 3. Mount back cover to the wall 4. Connect wiring at the back of Control Interface • Mount the back cover to the wall with screws via screw • Ensure that all wiring is tightly connected. All wiring must holes.
  • Page 5: 04. Wiring Diagram

    0-10V INPUT OUTPUT OUTDOOR COIL SENSOR SENSOR NOTE: DO NOT CONNECT SCREEN WIRE AT ACTRONAIR FACTORY WALL CONTROL SUPPLIED & FITTED POWER 485A WC-1 TWISTED PAIR 2: POWER POWER TO Vout TERMINAL GND TO GND TERMINAL DATA CABLE: 4 CORE (2 PAIR) TWISTED PAIR 7/0.20 (AWG24) MINIMUM...
  • Page 6: 05. Assigning Sensor

    CL01-2 Control Interface Installation Guide Important Notes for Return Air Temperature Sensor • SPLIT DUCTED UNITS (CAY/EVY or ELY) Leave the factory fitted Return Air Temperature Sensor in place. If disconnected, a fault will be registered and displayed in the screen. See the Split System Installation Guide, Air Temperature Setup for more details. •...
  • Page 7 CL01-2 Control Interface Installation Guide NOTE The Control Value is determined by the following example: Control Value calculation at Probe weight value of 50% : Control Value = 50% Room Temp + 50% Wall Cont Temp = (0.5 x 18.0) + (0.5 x 26.8) = 9.0 + 13.4 = 22.4 C (Displayed on CL01-2 as INSIDE temperature when...
  • Page 8 ©Copyright 2019 Actron Engineering Pty Limited ABN 34 002767240. ®Registered Trade Marks of Actron Engineering Pty Limited. ActronAir is constantly seeking ways to improve the design of it’s products, therefore specifications are subject to change without notice. Document: 9590-3026 Ver. 2 Issue Date: 09/2022...