Miscellaneous; Pipe Support; List Of Shortcuts; Rodgers Midi System Exclusive - Rodgers 538 insignia Owner's Manual

Classic organ
Table of Contents

Advertisement

8.

Miscellaneous

Pipe support

Rodgers organs support pipes that can be controlled via
MIDI.

List of shortcuts

Below please find a list of shortcuts that may come in
handy whenever you need to make make quick changes
to a given aspect. The plus sign ("+") means that you
need to press and hold the first piston while pressing
the second.
Shortcut
Function
[SET] + [®÷ª]
Calls up the "SONG RECORDER - Met-
ronome" page.
[SET] + [0]
Allows you to save general parameter
settings.
[SET] + [TREMULANT¥I] Calls up the "PIPE MODELING – Trem-
ulant I" page.
[SET] + [TREMULANT¥II] Calls up the "PIPE MODELING – Trem-
ulant II" page.
[SET] + General
Saves all eligible settings to a general
piston [1]~[8]
registration memory.
[SET] + Divisional
Saves all eligible settings to a divi-
piston [1]~[5]
sional registration memory (for Man-
ual I or II).
[SET] + [BASS] coupler Allows you to set the split point for
the [BASS] coupler range.
[SET] + [MELODY] cou-
Allows you to set the split point for
the [MELODY] coupler range.
pler
[SET] + [ORCH¥PEDAL] Calls up the "ORCHEST SETTING –
Pedal" page.
[SET] + [ORCH¥MAN.I] Calls up the "ORCHEST SETTING –
Manual I" page.
[SET] + [ORCH¥MAN.II] Calls up the "ORCHEST SETTING –
Manual II" page.
[SET] + [MIDI¥PEDAL]
Calls up the "MIDI SETTING– Pedal"
page.
[SET] + [MIDI¥MAN.I]
Calls up the "MIDI SETTING – Manua I"
page.
[SET] + [MIDI¥MAN.II]
Calls up the "MIDI SETTING –
Manual II" page.
Press and hold [M+]
Select the "CONSOLE – Memory Bank
– Set" page.

Rodgers MIDI System Exclusive

Rodgers organs use a subset of the Roland standard
MIDI System Exclusive format.
All Rodgers SysEx packets use the Roland "Data Set"
command, listed under "One Way Transfer Procedure"
in the Roland System Exclusive format specification.
The first five bytes of this type of packet are as follows:
Byte
Function
F0H
Begin System Exclusive
41H
Roland/Rodgers SysEx ID
10H
Device ID*
30H
Model ID (30 = Generic organ data)
(00 47 = 538/i548 data)
12H
Data Set Command
Note: This byte is usually 10H; however, the organ receives 00H~
0FH and can be set to transmit Device ID 00H or transmit and
receive any Device ID between 10H and 1FH.
See the last page of these notes for more information.
This header is then followed by the message body.
The message body contains a subcommand byte, an
optional offset byte and a variable number of data
bytes followed by a checksum byte and a MIDI End
Exclusive byte (F7). The checksum byte value is such
that if all bytes beginning with the subcommand byte
and ending with the checksum byte are added, the
lower 7 bits of the result will be all zeroes.
The following messages are used by Rodgers as of the
introduction of models 538/i548:
Rodgers 538/i548
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

I546 insignia

Table of Contents