minutes or pressing FOLLOW ME button again, the follow me function will be turned off automatically, and the
temperature collection function of room temperature sensor will be available, the PCB will control the unit according
to the room temperature detected from its own room temperature sensor and setting temperature.
9.19 Outdoor chassis heating cable function (optional)
Heating cable is fixed on outdoor chassis to help deicing and to avoid freezing. The heating cable's power is 85w,
rated voltage is 220v-240v, and is controlled by a thermostat. If outdoor temperature (sensed by outdoor thermostat) is
lower than 5℃, the thermostat closed and the heating cable begins to work. If outdoor temperature is higher than 15℃,
the thermostat opens and the heating cable stops working.
30