CI-1402
WOOD INSERT

SAFETY INFORMATION

WARNING
!
If the information in these instructions is not followed exactly, a
fi re or explosion may result causing property damage, personal
injury or death. Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage,
bodily injury or even death. Please read entire manual before
you install and use your appliance.
This appliance has not been tested with an unvented gas log
set. To reduce risk of fi re or injury, do not install an unvented
gas log set into the appliance.
- This appliance can be very hot when burning.
- Combustible materials such as fi rewood, wet clothing, etc. placed too
close can catch fi re.
- Children and pets must be kept from touching the appliance when it is hot.
- The chimney must be sound and free of cracks. Before installing this unit,
contact the local building or fi re authority and follow their guidelines.
- Operate only with the door tightly closed.
- Burn wood behind the log retainer directly on the fi rebricks.
- Do not use an elevated grate or otherwise raise the fi re.
- At least 14 square inches of outside air must be admitted to the room or
directly to the unit through a 4" diameter pipe.
- This appliance is designed to burn natural wood only. Higher effi ciencies
and lower emissions generally result when burning air dried seasoned
hardwoods, as compared to softwoods or to green or freshly cut
hardwoods.
- Do not start a fi re with chemicals or fl uids such as gasoline, engine oil,
etc.
- Do not burn treated wood, coal, charcoal, colored paper, cardboard,
solvents or garbage.
- Do not let the appliance become hot enough for any part to glow red.
- KEEP THE STOVE TOP TEMPERATURE BELOW 700°F (371°C). Attempts to
achieve heat output rates that exceed design specifi cations can result in
steel distortion and damage.
Phone (705)721-1212 • Fax (705)722-6031 • www.continentalfi replaces.com • ask@continentalfi re.on.ca
$10.00
OPERATING INSTRUCTIONS
DARDS: CSA B366.2, ULC S627, UL 1482.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
INSTALLATION AND
1.30
W415-0872 / B / 12.02.10
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CI-1402 and is the answer not in the manual?

Questions and answers

Summary of Contents for Continental Fireplaces CI-1402

  • Page 1: Safety Information

    CERTIFIED UNDER U.S. ENVIRONMENTAL PROTECTION AGENCY (E.P.A.) JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS BY E.E.M.C THESE STOVES HAVE BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STAN- DARDS: CSA B366.2, ULC S627, UL 1482. CI-1402 WOOD INSERT SAFETY INFORMATION...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS SPECIFICATIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION INSTALLATION PLANNING MINIMUM CLEARANCE TO COMBUSTIBLES INSTALLATION 4.0.1 TYPICAL EXISTING MASONRY 4.0.2 FACTORY BUILT FIREPLACE LOW CLEARANCE FLUE CONNECTOR (1402) FINISHING BRICKS AND BAFFLES INSTALLATION DOOR REMOVAL / INSTALLATION DOOR HANDLE INSTALLATION FLASHING INSTALLATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW Flashing, see “FLASHING” section Door, see “DOOR AND HANDLE INSTALLATION” section. Rating plate, see “RATING PLATE INFORMATION” Blower, see “BLOWER INSTALLATION” section. section. Draft, see, “AIR CONTROL” section. W415-0872 / B / 12.02.10...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS ” 44 ½” ” ” ” 5 ½” 31 ¼” 21 ½” 20 ¾” 19 ¾” ” 22 ¼” SPECIFICATIONS Specifi cations 1402 CHAMBER (D.W.H) 18x18x12” CAPACITY 2.25 ft APPROX. AREA HEATED* 800-2000 ft HEAT OUTPUT (HIGH BURN) ** 70,000 BTU DURATION LOW FIRE* 9 Hours...
  • Page 6: General Information

    • Before beginning your installation, consult with your local building code agency or fi re offi cials and insurance representative to ensure compliance. • Non-toxic smoke will be emitted during the paint curing process, to help dissipate the smoke open a window near the appliance.
  • Page 7 with a layer of fi bre baffl es at the top to maintain a high temperature in the combustion chamber so that gases mixing with the preheated air from the secondary air manifold tube are easily ignited and burned. The appli- ance sides and back are shielded to direct the heat upwards and forwards into the room.
  • Page 8: Rating Plate Information

    RATING PLATE INFORMATION For rating plate location, see LISTED SOLID FUEL BURNING SPACE HEATER / “INSTALLATION OVERVIEW” POÊLE À COMBUSTIBLE SOLIDE HOMOLOGUÉ TESTED TO: / TESTÉ SELON : UL1482 / ULC S627 / CSA B366.2 (DEC 92) section. MODEL / MODÈLE - EPA 1400 1400 1400L 1402...
  • Page 9: Installation Planning

    3.0 INSTALLATION PLANNING Clean all ashes out of the inside of the existing fi replace opening. Make sure that the chimney and fi replace are free of cracks, loose mortar, creosote deposits, blockage or other signs of deterioration. If necessary, have any repair work done by a qualifi...
  • Page 10: Installation

    4.0 INSTALLATION WARNING WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION. CAREFULLY FOLLOW THE INSTRUCTIONS FOR ASSEMBLY OF THE PIPE AND OTHER PARTS NEEDED TO INSTALL THE APPLIANCE. FAILURE TO DO SO MAY RESULT IN A FIRE, ESPECIALLY IF COMBUSTIBLES ARE TOO CLOSE TO THE APPLIANCE OR CHIMNEY AND AIR SPACES ARE BLOCKED, PREVENTING THE FREE MOVEMENT OF COOLING AIR.
  • Page 11: Typical Existing Masonry

    4.0.1 TYPICAL EXISTING MASONRY WARNING DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. You can install your appliance using your existing masonry chimney. To do FOLLOW MANUFACTURER’S so, follow the guidelines below.
  • Page 12: Factory Built Fireplace

    4.0.2 FACTORY BUILT FIREPLACE The following installation requirements must be observed when installing solid fuel burning inserts into factory built fi replaces. The factory built fi replace must be listed per UL 127 or ULC S610. Clearances to any combustible material surrounding this insert as identifi ed must be followed. These clearance requirements supersede any pre-existing facing material clearances listed for the factory built fi...
  • Page 13: Finishing

    5.0 FINISHING BRICKS AND BAFFLES INSTALLATION WARNING OPERATION OF THE APPLIANCE WITHOUT THE BAFFLES CAN RESULT IN EXCESSIVE TEMPERA- TURES THAT COULD DAMAGE THE APPLIANCE, CHIMNEY AND THE SURROUNDING ENCLOSURE. Install six (A) bricks along both sides of the appliance. Before installing the back bricks, loosen the screw holding the retainer and ensure that it has been moved forward.
  • Page 14: Door Removal / Installation

    DOOR REMOVAL / INSTALLATION WARNING BURNING YOUR APPLIANCE WITH THE DOORS OPEN OR AJAR CREATES A FIRE HAZARD THAT MAY RESULT IN A HOUSE AND OR CHIMNEY FIRE. DO NOT STRIKE OR SLAM DOOR. NEVER REMOVE THE DOOR WHEN THE APPLIANCE IS HOT. Hang the door using the hinge pins supplied.
  • Page 15: Flashing Installation

    FLASHING INSTALLATION The top fl ashing has been shipped fl at. To install the fl ashing, rest the bottom against the top of the appliance and secure using the tabs as illustrated below. Slide the trim over the fl ashing. W415-0872 / B / 12.02.10...
  • Page 16: Operation

    6.0 OPERATION WARNING ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR CLOSED AND LATCHED EXCEPT DURING START UP AND RE-FUELING OR WHEN USING THE SPARK SCREEN. ALWAYS WEAR GLOVES TO PREVENT INJURY. DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED OR WHEN USING A SPARK SCREEN AS UNSTABLE WOOD COULD FALL OUT OF THE FIRE CHAMBER CREATING A FIRE HAZARD TO YOUR HOME.
  • Page 17: Blower

    You can now add larger pieces of wood and operate the appliance normally. Once the appliance is entirely hot, it will burn very effi ciently with little smoke from the chimney. There will be a bed of orange coals in the fi rebox and secondary fl...
  • Page 18: Air Control

    AIR CONTROL Draft is the force which moves air from the fi rebox up ASH LIP through the chimney. The amount of draft in your chimney depends on the length and diameter of chimney, local ge- ography, nearby obstructions and other factors including the amount of heat generated by the fi...
  • Page 19: Fuel

    FUEL THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED WOOD, COAL, CHARCOAL, COLOURED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THE APPLIANCE.
  • Page 20: Lighting A Fire

    LIGHTING A FIRE 6.5.1 FLASH FIRE A fl ash fi re is a small fi re burned quickly when you don't need much heat. After your kindling has "caught", load at least 3 pieces of wood, stacked loosely. Burn with the draft control fully open or closed only slightly.
  • Page 21: Maintenance

    7.0 MAINTENANCE WARNING TURN OFF THE POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established.
  • Page 22: Runaway Or Chimney Fire

    RUNAWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRES ARE NOT COVERED BY THE LIFETIME LIMITED WARRANTY. CAUSES: • Using incorrect fuel, or small fuel pieces which would normally be used as kindling. •...
  • Page 23: Glass Replacement

    GLASS REPLACEMENT WARNING DO NOT USE SUBSTITUTE MATERIALS. GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED. CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE APPLIANCE BEFORE OPERATION.
  • Page 24: Care Of Glass

    CARE OF GLASS If the glass is not kept clean permanent discolouration and / or WARNING blemishes may result. Normally a hot fi re will clean the glass. The most common reasons for dirty glass include: not using HOT GLASS WILL suffi...
  • Page 25: Blower Service Or Replacement

    BLOWER SERVICE OR REPLACEMENT Turn off all electrical power to the insert. Remove the glass door and set aside in a safe place. BLOWER Remove the two screws from the outer edge of the side panel(s). HEAT RHEOSTAT BLOWER SENSOR Push the side panel toward the door and pull away from the insert, releasing the panel from the keyed slot.
  • Page 26: Replacements

    8.0 REPLACEMENTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all parts can be ordered through your Authorized dealer / distributor. FOR WARRANTY REPLACEMENT PARTS, A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM.
  • Page 27 ACCESSORIES REF NO. PART NO. DESCRIPTION H222-G GOLD PLATED DOOR H222 BLACK DOOR H222-SS BRUSHED STAINLESS STEEL DOOR - STANDARD ARCH H222-W BLACK DOOR - EARLY AMERICAN H222-GW GOLD DOOR - EARLY AMERICAN H222-SSW BRUSHED STAINLESS STEEL DOOR - EARLY AMERICAN CISK** CAST IRON SURROUND KIT - PAINTED BLACK CISK**A...
  • Page 28: Trouble Shooting

    9.0 TROUBLE SHOOTING WARNING TURN OFF THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS. WHEN CHECKING CONNECTIONS, INSTALLING JUMPER WIRES (FOR TEST PURPOSES ONLY) OR REPLACING COMPONENTS, UNPLUG HEATER FROM THE RECEPTACLE TO PREVENT ELECTRICAL SHOCK OR DAMAGE TO THE COMPONENT.
  • Page 29: Warranty

    10.0 WARRANTY CONTINENTAL® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2008 Quality Assurance Certifi cate. CONTINENTAL® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete appliance is again thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, receives the quality product that you expect from CONTINENTAL®.
  • Page 30: Service History

    11.0 SERVICE HISTORY 43.1 W415-0872 / B / 12.02.10...