Setup; Ac Power; Fuse Replacement; Fuse Replacement Diagram - Chauvet Freedom Par Tri-6 User Manual

Hide thumbs Also See for Freedom Par Tri-6:
Table of Contents

Advertisement

3. S
ETUP

AC Power

Fuse
Replacement
Fuse
Replacement
Diagram
Freedom™ Par Tri-6 User Manual Rev. 1
The Freedom™ Par Tri-6 has an internal auto-ranging power supply and it can work with an input voltage
range of 100 to 240 VAC, 50/60 Hz.
Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the product
has an appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or
dimmer channel serves only as a 0 to 100% switch.
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3.
Pry the fuse holder out of the housing.
4.
Remove the blown fuse from the holder.
5.
Replace with a fuse of the exact same type and rating.
6.
Insert the fuse holder back in place and reconnect power.
Disconnect the product from power before replacing the fuse.
Spare Fuse
holder (inside
safety cap)
Always replace a blown fuse with another of the same type and rating.
A spare fuse is not included; however, the safety cap has room for a spare.
Installed Fuse
(held by plastic clip)
Safety
Cap
Page 7 of 22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents