More than one Power Supply in a System

NB! All of the Yoga Smart Home system's 12VDC power supply grounds (GND) must be connected together!
Drawing: 12VDC Power Connection
This is necessary for RS485 line potential equalization; otherwise, traffic on the YogaBus line might be cor-
rupted. If input/output decoupling is used (see Yoga Input/Output Controller description), the decoupled part's
power supply Power and GND may not be connected together with the rest of the system.