Sony STR-K990 Service Manual page 2

Multichannel av receiver
Hide thumbs Also See for STR-K990:
Table of Contents

Advertisement

STR-K990
QQ
3 7 63 1515 0
Video section
Inputs/Outputs
Video:
1 Vp-p, 75 ohms
COMPONENT VIDEO:
Y: 1 Vp-p, 75 ohms
P
/C
: 0.7 Vp-p, 75 ohms
B
B
P
/C
: 0.7 Vp-p, 75 ohms
R
R
80 MHz HD Pass Through
General
Power requirements
Area code
Power requirements
US, Canadian
120 V AC, 60 Hz
Power output (DIGITAL MEDIA PORT)
DC OUT:
5V, 700 mA
Power consumption
Area code
Power consumption
US
200 W
Canadian
270 VA
Power consumption (during standby mode)
0.3 W
Dimensions (width/height/depth) (Approx.)
17 × 6 1/4 × 12 1/4 inches
(430 × 157.5 × 310 mm)
including projecting parts
TE
and controls
L 13942296513
Mass (Approx.)
17 lb 4 oz (7.8 kg)
Design and specifications are subject to change without notice.
www
.
2
http://www.xiaoyu163.com
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, "metallized" knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes.).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers' instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The "limit" indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples
of a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2 V AC range are suitable. (See
Fig. A)
To Exposed Metal
Parts on Set
Q Q
3
6 7
1 3
1 5
0.15 µ F
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE
WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE
PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR
IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 0 SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES
PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE
FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS
co
PUBLIÉS PAR SONY.
.
9 4
2 8
0 5
8
2 9
9 4
2 8
AC
1.5 k Ω
voltmeter
(0.75 V)
Earth Ground
m
9 9
9 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents