FiT FiT239-Color User Manual

Professional breath alcohol analyzer

Advertisement

Quick Links

Professional Breath Alcohol Analyzer
With Fuel Cell Sensor
FiT239-Color
IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell in
human mouth, etc...) may affect the Blood Alcohol Concentration (BAC) level, so the
Readings are For Reference Only.
Neither the reseller nor manufacturer accept any liability arising from the use of this unit
DO NOT drink before you drive!
1
2009-3-6
FiT239-C 239-09Y03543

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FiT239-Color and is the answer not in the manual?

Questions and answers

Summary of Contents for FiT FiT239-Color

  • Page 1 Professional Breath Alcohol Analyzer With Fuel Cell Sensor FiT239-Color IMPORTANT: Many factors (e.g. environment gas residue, smoke & various smell in human mouth, etc…) may affect the Blood Alcohol Concentration (BAC) level, so the Readings are For Reference Only. Neither the reseller nor manufacturer accept any liability arising from the use of this unit...
  • Page 2: Intended Use

    Serviced or repaired by personnel not employed by FiT Service centre or authorized by FiT or if the instrument is used in a manner not conforming to its intended use.
  • Page 3: Operation Instructions

    Operation instructions (User can use either normal keys or touch screen for key operation) Power up ① Install the rechargeable battery (Nokia standard) into the battery compartment. ② Press the “OK” key 3 seconds to turn ON the tester, than enter into the main interface. Press the “OK” key few seconds (above 3 seconds) to turn OFF the tester.
  • Page 4 If the LCD display shows "The period of validity is overtimes!", it need to reset the test times. enter the calibration mode by input the supervisor password. Only perform this function 2.4 Alcohol Calibrate: by FiT or FiT Authorized service center 2.5 Test record: 2.5.1. Review all records by press “Back” or “Next” icon.
  • Page 5: Test Record

    31780405 or by e-mailing support@group-fit.com How often should I re-calibrate the FiT tester? The FiT tester can remain accurate for 6 months of use. The more frequent the use, the more the unit will need to be calibrated. 2009-3-6 FiT239-C 239-09Y03543...
  • Page 6 According to D/N31051, we recommend recalibration on a 6 monthly (or earlier) basis to ensure maximum accuracy. NB* It is important to observe the recommended 20 minute pause without consuming any alcohol, cigarettes or anything else before testing. Failure to do this can shorten the life of the sensor. In such cases, the sensor can be permanently damaged or may need more frequent calibration.